Parameters of Atomic Absorption Spectrophotometer AA2300
185-910nm AAS-Atomic Absorption Spectrometer for Precise Measurements | |
---|---|
Technical Parameters | Value |
Atomization Source | Flame, Graphite Furnace, Electrothermal |
Injection Position | 108 positions |
Wavelength Range | 185-910nm |
Power Supply | AC220V, 50Hz |
Background Correction | D2 Background Correction |
Name | Atomic Absorption Spectrophotometer |
Weight | 280kgs |
Spectral Bandwidth | 0.1, 0.2, 0.4, 1.0, 2.0nm |
Data Storage | USB, PC |
Light Source | Halogens, Deuterium, Tungsten |
Optical System | |
Wavelength Error | ±0.15nm |
Wavelength Repeatability | ≤0.05nm |
Flame Atomizer | |
Detection Limit (LOD) | Cu by flame method:≤0.002ug/mL |
Repeatability | RSD≤0.25% |
Burning Head | Full titanium |
Graphite Furnace Atomizer | |
Detection Limit (Cd) | ≤0.3pg |
Repeatability | RSD≤1.5% |
Autosampler | |
Linearity | >0.999 |
Injection Volume | 1~200μL |
Injection Volume Repeatability | ≤0.1% |
Repeatability of Results | ≤1.5% |
Features of Atomic Absorption Spectrophotometer AA2300
1. Stability: Double-beam system can automatically compensate the
light source drift and wavelength drift caused by the variation of
temperature (with the function of the eliminating the affection of
wavelength drift on the base line stability) and electronic circuit
drift so as to reach a good basic line stability.
2. Full-reflection dual-beam optical path, high optical path
stability
3. High precision of measurement: Gas path system is equipped with
precision pressure stabilizing and current stabilizing devices to
reach stable flame and low noise. Specially designed fine light
beam passes through the flame to ensure a high precision analytical
test and low characteristic concentration.
4. 8 lamp holders preheat simultaneously to improve detection
efficiency
Applications of Atomic Absorption Spectrophotometer
Atomic absorption spectrometer has been widely used in the analysis of macro and micro trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food, environmental monitoring and etc.
Flame: metal processing, mining, electroplating, soil fertilizer and etc.
Flame + Graphite Furnace: disease control, pharmacy, food, food additives, water plant, power plant water quality inspection, commodity inspection and etc.
Flame + Hydride Generator: feed, veterinary drugs, food additives, labor protection, etc.