Infusion Pump Ion Chromatography Instruments for Detection of Iodine in Water Quality


Introduction of Ion Chromatography Instrument

Ion chromatography is a form of liquid chromatography used to separate ions in aqueous solutions. Typically, IC analyzes anions such as fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulfate. Ion chromatography can detect other ions as well. Chromate, perchlorate, and organic acids are examples.


Features of Ion Chromatography Instrument

1. Intergrated apperance design, high brightness LCD full touch GUI controller.
2. High degree of automation "One Key Rinse" and "One Key Maintenance" automatic maintenance function.
3. Higher intergration: Support optional parts upgrade to 2D system and multi-detector combination.
4. Full PEEK pump and electric injection valve.

5. Powerful and convenient chromatpgraphy workstation.

6. High precision temperatur-controlled conductivity detector.


Technical Data of Ion Chromatography Instrument

Infusion Pump Ion Chromatography Instrument For Iodine In Water Quality

System Parameter
Qualitative Repeatability≤0.5%
Quantitative Repeatability≤1%
Pump System
Flow Rate(0.001~10.000)mL/min
Pump Head Pressure Resistance(0 ~ 35) MPa
Flow Rate Setting Inaccuracy<0.1%
Flow Stability<0.1%
Pressure Display Accuracy0.01Mpa
Pressure Pulsation<0.5%
Conductivity Detector
Baseline Noise≤0.1%FS
Baseline Drift≤0.5%FS
Minimum Detectable Concentration (Cl)≤0.0002μg/mL
Minimum Detection Concentration (Li)≤0.0001μg/mL
Conductivity Cell Volume≤ 0.6μL
Conductivity Detection Range0-15000μS/cm
Detector Resolution0.00238nS/cm
Conductivity Cell Temperature Setting Error±0.01°C
Resolution of Conductivity Cell Temperature Display0.001°C
Suppressor
Constant Current Source Range0-500mA in 0.1mA increments
Column Oven
Temperature RangeRoom temperature +5°C~85°C
Control Temperature Stability≤ 0.1°C
Autosampler
Number of Sample Vials≥ 120 (1.5mL standard sample bottle)
Repeatability

Full loop injection < 0.3% RSD,

Partial injection < 0.5% RSD,

Non-destructive injection < 1 % RSD (injection volume > 5uL)

Syringe SizeStandard: 500μL; optional; 250μL, 1000μL, 2500μL
Loop SizeStandard: 100μL; optional: 20μL, 50μL, 200μL
Linearity>0.999
Cross-contamination<0.01%
Eluent Generator
Flow Rate Range0.001 to 3.000mL/min
Eluent Concentration RangeKOH, MSA-0.1 to 100mM
Concentration Accuracy0.1mM
Original Concentration of Electrolyte25% KOH/MSA
Volume of Electrolyte1000mL
Maximum Working Pressure21MPa (3000psi)
Gradient Accuracy1.5%

Industry Application

Application of ion chromatography in ambient air
1. Detection of anions, cations, organic acids, hexavalent chromium, ammonia and organic ammonia in particulate matter in ambient air.

2. Detection of anions and cations in atmospheric precipitation.