AC DC Hipot EV Electrical Safety Testing Equipment For Electric Vehicle

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SNE6163B
Minimum Order Quantity:1
Delivery Time:30 days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

Multifunctional Comprehensive Electrical Safety Testing Equipment


Equipment Overview



1. 10 memory groups, 8 test steps, can quickly switch between groups.


2. The test voltage rises and falls slowly (time controllable) to meet the test requirements of different industries.


3. The upper and lower limits of the current can be set to determine, sound and light alarms, and eliminate product missed inspections.


4. With keyboard lock function, effectively prevent wrong operation.


5. Perfect protection function: DC high voltage rapid discharge device during DC withstand voltage test, to avoid residual voltage on the tested object, which may cause electric shock hazard; prevent high voltage electric shock circuit, detect loop at any time, prevent electric shock injury, and ensure personnel safety.


6. The charging lower limit function can detect whether the circuit is disconnected and improve the reliability of the test.


7. Optional arc detection function.


8. Different communication addresses can be configured to facilitate networked system management.


Functions and Features



Test function descriptionAC withstand voltage, DC withstand voltage, insulation function
Working conditionsPower supplyAC220V±10%, 50/60Hz±5%
Environmental Temperature0-40℃
Environmental Humidity20-80%RH
No-load power consumption of the whole machine<15W
Display methodLCD
Overcurrent protectionFuse, software protection
Alarm methodSound and light alarm: buzzer, indicator light
Number of test groups10 memory groups, each with 8 test steps
Function configurationRemote control interfaceExternal start and stop signals can be connected
Switch output interfaceQualified, unqualified, testing
Communication functionRS232
USB interfaceQualified, unqualified, testing

Technical Parameters



Insulation Resistance TestStandards applied: IEC60335, IEC60601, UL60950, IEC60598, etc
Rated output3000V/10GΩ 1000V/3GΩ
Output voltage rippleResistive load, 1000V/2mA, <1%
Output voltage setting range

DC:100-3000V continuously adjustable

DC: 100-1000V continuously adjustable

Output voltage accuracy± (1% setting value+2V) ± (2% setting value+2V)
Insulation resistance setting range

Upper limit: 0.00-99.99-9999MΩ, 0=closed, Lower limit: 0.10-99.99-9999MΩ

Upper limit: 0.00-99.99-3000MΩ, 0=closed, Lower limit: 0.10-99.99-3000MΩ

Insulation resistance measurement range/resolution

0.100-9.999-99.99-999.9-9999GΩ, 0.001 MΩ/0.01 MΩ/0.1 MΩ/1 MΩ

0.100-9.999-99.99-999.9-3000GΩ, 0.001 MΩ/0.01 MΩ/0.1 MΩ/1 MΩ

Resistance compensation>30MΩ
Insulation resistance measurement accuracy

0.100MΩ-9.999MΩ-10.00MΩ-99.99MΩ-100.0 MΩ-999.9 MΩ-9999 MΩ

100-499V: 0.050-9.999 MΩ, 10.00-99.99 MΩ, 100.0-999.9 MΩ, 1000-2000 MΩ, ± (5% reading value+2 words)

500-1000V: 0.050-9.999MΩ, ± (2% reading value+2 words); 1000-3000 MΩ, ± (5% reading value+2 words); 3000-9999MΩ± (15% reading value+5 words)

Charging lower limit current0~3.500uA, automatic/manual
Slow rise/slow fall time setting0.1-999.9s (0=close)
Delay/test time setting range0.5-999.9s / 0.0 (0.0= Continuously output), 0.1-999.9s
AC Withstand Voltage TestStandards applied: IEC60335, IEC60601, UL60950, IEC60598, etc
Withstand voltage test typeCold state withstands voltage test
Rated output load100VA (AC: 5000V/20mA)
Output voltage setting rangeAC: 100-5000V
Output voltage resolution/accuracy

± (1%× setting value +2V)

± (2%× setting value +2V)

Output frequency50Hz or 60Hz
Original Voltage Setting(0~50%×setting voltage)
Current setting range/current zero

Upper limit: 0.000-3.999-20.00mA

Lower limit: 0.000-3.999-20.00mA

Zero current0.000—20.00mA, automatic or manual
Current measurement range/resolution

0.010-3.999-20.00mA

0.001mA/0.01mA

Current measurement accuracy

± (1% reading value +2 words)

± (2% reading value +2 words)

Rise time/slow down time0.1-999.9s
Test time setting range0.0 (0.0= Continuous output), 0.1-999.9s
Arc detectionLevel 1-9, No.9 is the most sensitive level, 0 = closed (optional)
DC Withstand Voltage TestStandards applied: IEC60335, IEC60601, UL60950, IEC60598, etc
Withstand voltage test typeCold state withstands voltage test
Rated output loadDC: 100-6000V
Output voltage resolution/accuracy

± (1% setting value +2V)

± (2% setting value +2V)

Original Voltage Setting(0~50%×setting voltage)
Current setting range

Upper limit: 0.000-0.399-3.999-10.00mA

Lower limit: 0.000-0.399-3.999-10.00mA

Current measurement range/current zero

0.000-0.399-3.999-10.00mA / 0.000-2.000mA

Automatic or Manual

Zero current0.000—10.00mA, automatic or manual
Current measurement range/accuracy

0.010-3.999-10.00mA

± (1% reading value+2 words)

± (2% reading value+2 words)

Rise time/slow down time0.1-999.9s
Test time setting range0.0 (0.0=Continuous output), 0.1-999.9s
Slowly rising upper limit current0.000-10.00mA (0=close)
Charging lower limit current0.0-350.0uA DC, automatic or Manual
Arc detectionLevel 1-9, No.9 is the most sensitive level, 0 = closed (optional)