IEC 60332 Single Insulated Cable Vertical Flammability Chamber

Brand Name:Sinuo
Certification:Calibration Certificate (Cost Additional)
Model Number:SN775
Minimum Order Quantity:1
Delivery Time:30 days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone, Shibi Street, Panyu District, Guangzhou, China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

IEC 60332 Single Insulated Cable Vertical Flammability Test Chamber


Complied Standards & Clauses


IEC 60332-1-1 “Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus”


IEC 60332-1-2 “Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame”


IEC 60332-1-3 “Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flamingdroplets/particles”


Equipments Overview


Samples and Restrictions: Single insulated wire or cable.


Application: It is suitable for vertical burning test of a single insulated wire, cable or optical fibre cable to determine the burning characteristics of its insulating material.


Test Principle: Integral air-intake automatic ignition system is adopted, and the combustion delay is only 0.1 seconds to ensure full combustion of gas.


Structure: Chamber structure, fume hood is optional.


Technical Parameters


Control and Operation Mode

Electric control button operation

(PLC control 7-inch color touch screen operation is optiona)

BurnerIEC 60695-11-2 Annex A, burner opening Φ7±0.05mm, made of brass
Gas Flow and Gas Source TypeMixed gas: 650±30mL/min propane; 10±0.5L/min air, adjusted by dual flow meters
Burning Time9999X0.1S
Burning AngleTilt 45°±2°, adjustable
Test Flame VerificationTemperature measuring copper head: 500W: Ф9mm±0.01mm, 10±0.05g before drilling
Thermocouple: American original Omega φ0.5 armored nickel-chromium/nickel aluminum wire, K type, temperature resistance 1100°
Distance between Bunsen burner port and temperature measuring copper block: 95 mm
Flame height: inner flame 55±5mm, outer flame 180±10mm
The heating time from 100±5°C to 700°±3°C is 45±5s
Test chamber DimensionWDH=300×450×1200±25mm
Gas>95% propane gas or coal gas
Requirements of SampleLength: 600±25mm, 50mm from the bottom of the chamber
Horizontal Support Sample FixturesTwo, distance 550mm
External DimensionsWDH=1100×600×1550mm,Weight about 160kg, equipped with fume hood

Details


China IEC 60332 Single Insulated Cable Vertical Flammability Chamber supplier

IEC 60332 Single Insulated Cable Vertical Flammability Chamber

Inquiry Cart 0