Electric Vehicle Charging Pile Impulse Voltages Generator
Complied Standards & Clauses for Electric Vehicle Charging Pile Impulse Voltages Generator
The Impulse Test Generator conforms to the standard requirements of IEC 60664-1 clause 6.2.2.1, required by IEC 61851-1 clause 12.7 and IEC 61851-23 clause 11.4, etc.
It is used to verify that the appliances shall withstand the transient over-voltages to which they may be subjected. The impulse voltage test is a destructive test in which a breakdown occurs if the test specimen cannot withstand the applied voltage. When the sample breaks down, sparks and discharge sounds will be generated. The peak voltage of the instrument will drop significantly (close to zero) when it is no-load. When the same voltage is applied again, the above phenomenon will occur.
Technical Parameters for Electric Vehicle Charging Pile Impulse Voltages Generator
Model | SN1104-20KV |
DC high voltage | 20kV (Max) ±5% |
Impulse voltage wave | Impulse wavefront time: 1.2 µs ± 30 %; Half value of after wave time: 50 µs ± 20 % Please note that the waveform should be checked on an external oscilloscope |
Instrument internal resistance | 2Ω ± 10%and 500Ω± 10% |
Peak voltage: 300 V~ 20kV | 300V-20kV, Low: 300 V~ 2,500V, High: 2,500 V~ 20kV |
Impact interval time | 1 ~ 99s can be preset |
Impact cycles | 1 ~ 9999 |
Polarity | Positive and negative |
Working power source | Rated voltage: ~ 220V±10%, 50/60Hz |
Use environment | Temperature: 15°C-35°C, relative humidity 10%-75% |
Dimension | 600mm×570mm×1500mm |
Weight | 90 KG |
6kV open circuit voltage output waveform (1000:1)
Please note that the waveform should be checked on an external oscilloscope