Add to Cart
UL 1642 Lithium Battery Acupuncture Tester Battery PLC Control Testing Equipment
Complied Standards & Clauses
Conforms to UL 1642, etc.
Product Overview
The tester is used to simulate the conditions in which various
types of batteries are exposed to needle puncture when used,
transported, stored or disposed of household waste.
The test should be carried out at an ambient temperature of 20℃±5℃,
and the battery connected to the thermocouple (the contact of the
thermocouple is fixed on the large surface of the battery) is
placed in a fume hood. Use a non-corrosive steel needle with a
diameter of 2-8mm to pierce the center of the largest surface of
the battery at a speed of 10mm/s to 40mm/s, hold it for any time
and observe the test results. If the battery does not explode or
catch fire, it is considered qualified.
Technical Parameters
tem | Parameters |
Power supply | AC220V±10%/50Hz |
Test station | Single station |
Operation interface | 7-inch color LCD touch screen |
Drive mode | Servo Motor |
Control method | PLC Control |
Test force range | 0~3000N |
Residence time | 0~9999.9s, can be preset |
Test stroke | 0~200mm, can be preset |
Test speed | 0~40mm/s, can be preset |
Test environment | Atmospheric pressure 80~106kpa; ambient temperature 5~40°C; relative humidity (20~90)%RH. Use place: no violent shaking, vibration, no electromagnetic interference, no dust, no explosive and corrosive gas, good heat dissipation |
Details