Cold Heat Humidity and Dryness Testing Temperature and Humidity Chamber 80L
Complied Standards & Clauses
IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”
IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”
IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”
IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”
Equipment Overview
The purpose is to confirm the product's reliability of storage and transportation under high and low temperature alternating heat and humidity. This test chamber is used for cold, heat, humidity and dryness testing of raw materials and devices such as electronics, electricians, electrical appliances, plastics, etc.
Technical Parameters
Technical Parameters | ||
Control & Operation | PLC and touch screen intelligent control system | |
Chamber Size | Inner Size | External Size |
400*500*400 mm | 780*1650*1250 mm | |
Temperature Range | -40 °C ~+150°C | |
Humidity Range | 20%~98%RH | |
Temperature fluctuation | ±0.5℃ | |
Temperature deviation | ≤±2.0℃ | |
Humidity fluctuation | ≤2.5% | |
Humidity Deviation | ≤±3% | |
Heating Rate | ≧2-3°C/min | |
Cooling Rate | ≧1°C/min, average no load | |
Load condition | None | |
Working noise | A sound level≤70dB(A) (Measured in a soundproof room with an ambient temperature of 25°C and low echo. Using A weighting, test the average of 9 points. Each test point is 1 meter away from the noise source horizontally and 1 meter above the ground.) |
Structural features | |
Insulation enclosure structure | 1. Outer wall material: A3 board spraying. 2. Inner wall material: brushed stainless steel plate SUS﹟304. 3. Chamber thermal insulation material: 100mm high temperature resistant rigid polyurethane foam. 4. Chamber door insulation material: 100mm high temperature resistant rigid polyurethane foam. |
Bottom structure strength | The weight capacity of the track at the bottom of the test chamber: ≤100Kg/m² (load) |
Air conditioning channel | 1. Stainless steel long-axis centrifugal fans: 1 set/90W. 2. Fan, heater, evaporator (also dehumidifier), drainage device, pressure balance port, adjustable air deflector, temperature sensor |
Standard configuration of test chamber | 1. Observation window: 400x600x40mm 3-layer vacuum tempered glass 2. Flat embedded handles 3. Door hinges: SUS #304 imported hinges 4. Energy-saving lamp inside the chamber 5. Lead hole: φ50mm 1 piece |
Chamber door | 1. The single-piece door opens outwards, with the hinge on the left and the handle on the right (when facing the front of the box). 2. Equipped with a safety door locking mechanism (the door can be opened in the test room), the door is equipped with electric heat to prevent condensation, and the visible range of the insulating glass observation window (W400×H600mm). The door frame is equipped with an anti-condensation electric heating device. |