Add to Cart
Low price 48*96 mm LCD display single phase digital multimeter
Performance Characteristics | |||||
High precision measurement of three phase voltage, three phase current, active power, reactive power, apparent power, power factor, frequency of electric parameters | |||||
Forward and reverse active or reactive energy measurement | |||||
Division of electric energy metering, time-sharing power timing meter reading | |||||
Measurement of three-phase voltage, three-phase current total harmonic distortion (THD), 2-31 odd harmonic component | |||||
Provide the digital tube display, local data query | |||||
Menu button intuitive, simple operation | |||||
Current, voltage gain programmable setting | |||||
Programmable voltage ratio | |||||
Support for fire control, remote cut off the fault circuit | |||||
Provide multiple loop control nodes, can be used for the alarm, trip control | |||||
Support for RS-485 communication, Modubus-RTU protocol | |||||
Support for switching input, output, analog quantity transmitting output | |||||
Convenient installation, wiring is simple, small engineering quantity | |||||
A wide range of AC/DC power supply: AC/DC 80-270V | |||||
To be completed by SCADA, PLC in a variety of communications software network | |||||
Technical Index | |||||
Accuracy of measurement | voltage level 0.5, current level 0.5, active power 0.5, reactive power level 0.5,Frequency ±0.02Hz, active electric energy class 0.5s or class 0.2s, reactive energy grade 1 or grade 2, power factor 0.5 | ||||
Singal input | Connection mode of four phase three wire, three phase three line | ||||
Rated voltage of AC 57.7V, AC 100V, AC 220V, AC 380V | |||||
Over load 1.2 times ( Continued ), 2 times / second ( instantaneous ) | |||||
Power <1VA/ phase | |||||
Impedance >300KΩ, current: <20mΩ | |||||
The frequency of 45~65Hz | |||||
Auxiliary power supply | Working range of AC/DC 80V~270V | ||||
Power consumption <4VA | |||||
Function module | Communication interface 1 way RS-485 communication, Modbus-RTU protocol | ||||
Baud rate: 1200~9600bps, the default 2400bps | |||||
Switch input support 4 stem node input | |||||
The switch output support 3 relay output, capacity: AC 250V/5A, DC 30V/5A | |||||
Transmission output support 3 analog output: 0/4~20mA or 0~5/10V | |||||
Environment | Working temperature:-10°C ~+55°C | ||||
Storage temperature:-25°C ~+70°C | |||||
Relative humidity is less than 93%, no corrosive gas | |||||
Elevation≤2500m | |||||
Safety | Insulation resistance >100MΩ | ||||
AC withstand voltage AC 2KV | |||||
Electromagnetic compatibility | ESD level 4 | ||||
Electrical fast transient burst level 4 | |||||
Selcction ofSpecification | |||||
Digital Panel Meter with A V Hz Cos W Var Kwh Varh(9999 display programmable) | |||||
Model NO. | Display | Frame size(mm) | Hole size(mm) | Remark | |
CN-D1Y | LCD | 160*80 | 152*76 | ||
CN-D2Y | LCD | 120*120 | 111*111 | ||
CN-D3Y | lCD | 96*96 | 92*92 | ||
CN-D4Y | LCD | 120*60 | 114*56 | ||
CN-D5Y | LCD | 96*48 | 92*45 | ||
CN-D6Y | LCD | 72*72 | 68*68 | ||
CN-D7Y | LCD | 80*80 | 76*76 | ||
Extended Modules: | |||||
AC/DC power supply(switching power supply)$4 | |||||
AO: $7 more for each stem node | |||||
DI: $4 more for each stem node | |||||
DO:$4 more for each stem node | |||||
“*” means unconventional products of our corporation |