DSC-600 DSC Differential Scanning Calorimetry TGA DTA DSC Analyzer

Brand Name:BonninTech
Certification:CE, ISO
Model Number:DSC-600, DSC-1000
Minimum Order Quantity:1 set
Delivery Time:5-10 days
Payment Terms:T/T
Contact Now

Add to Cart

Site Member
Location: Wuhan China
Address: No. 119 Guannan Industrial Park, East Lake High-Tech Development District, Wuhan, China
Supplier`s last login times: within 32 hours
Product Details Company Profile
Product Details

Application areas

The differential scanning calorimeter is designed for the measurement of DSC thermal analysis in plastics and rubber industry, can be glass transition temperature test, phase transition test, melting and enthalpy test, product stability, oxidation induction test, etc. (Tg, Tc, Tm, enthalphy of crystallization, enthalphy of melting & crystallinity in %, OIT, etc). This instruments conforming to national standards GB / T 19466.2 - 2004 / ISO 11357-2: 1999 Part 2: Determination of glass transition temperature, GB / T 19466.3 - 2004 / ISO 11357-3: 1999 Part 3: Melting and crystallization temperature and Determination of enthalpy. Oxidation Induction Time (OIT), which is a measure of the time taken for the sample to start an autocatalytic oxidation reaction at elevated temperatures (200 degrees Celsius) and is an indicator of the ability of the material to resist thermal degradation during forming, storage, welding, and use. ISO 11357-3: 1999, Part 6 Oxidation induction period. Oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) determination. Oxidation induction period has been included in the pipeline industry and wire and cable inspection range.


Instrument principle

Differential scanning calorimetry is under the control of the program temperature, the measurement of material and reference power between the temperature difference with a change in technology. The DSC series differential scanning calorimeter is mainly composed of heating furnace, host, microvolt amplifier, A / D converter, data acquisition system, gas flow control system, computer, printer and other components, and supplemented by two atmosphere The measurement results are processed by a computer data processing system.


Main feature

  • Industrial-grade widescreen touch structure, display rich information, including set temperature, sample temperature, oxygen flow,
  • Nitrogen flow, differential thermal signals, a variety of switch states, flow zero.
  • USB communication interface, versatility, reliable communication without interruption, support for self-recovery connection.
  • Furnace structure is compact, adjustable heating rate can be adjusted.
  • Improve the installation process, all of the mechanical fixed way to completely avoid the body of the colloids of the differential thermal signal pollution.
    Dual temperature probe, to ensure high temperature measurement sample repeatability. All the way temperature probe installed in the furnace wall for PID control the temperature of the entire furnace, but because of the thermal inertia of the temperature, the temperature transmitted to the sample has a certain deviation, and spring, summer, fall and winter deviations vary, so the use of single temperature Probe temperature and temperature control, either differential heat signal or temperature signal, the error is relatively large; the instrument at the bottom of the sample to install a more temperature probe for measuring the true temperature of the sample, and the use of our special temperature control technology, control the furnace wall temperature so that the sample temperature reaches the set temperature.
  • Digital gas mass flow meter automatically switches two atmosphere flow, switching speed, short stabilization time.
  • Standard sample to facilitate customers to calibrate the constant temperature coefficient.
  • Software adaptive resolution of the computer screen, the software automatically adjusts the curve according to the size of the computer screen display. Support laptop, desktop; support Win2000, XP, VISTA, WIN7 and other operating systems.

Technical parameter

DSC range0~±500mWTemperature range

Room

temperature

~500℃/800℃/1500℃

Heating rate0.1~80℃/minTemperature resolution0.01℃
Temperature accuracy±0.1℃Temperature repeatability±0.1℃
DSC accuracy±2%DSC resolution0.01mW
DSC resolution0.01mWTemperature control method

Constant

temperature, programs control

automatically

Temperature

control mode

Rise in temperatureAtmosphere control of gas

Nitrogen,oxygen

(instrument

changes

automatically)

Gas flow0-200mL/minGas pressure0.2MPa

Accuracy of

gas flow

0.2mL/minMatching crucible

Alumina crucible

Φ6.7*3mm

Standard

sample

Equipped with standardmaterial

(indium ,tin, zinc)

the user can correct the

temperature and enthalpy

Data communication interface

standard USB

interface

Display

method

24bit color,7 inch touch

screen

Power supply

AC220V

50Hz/60Hz

Size

(W * D * H)

42*38*27cmNet weight14.5KG
Packing size (W * D * H)58*45*40cmGross weight23.5KG

FAQ 1. Are you a factory or trading company?

We are a factory.


FAQ 2. Can you supply OEM?

OEM is available.


FAQ 3. What's the MOQ ?

(1). MOQ is 1 piece. The disposable supplies order usually at least 1 box.


FAQ 4. How about the order processing and lead time?

After order confirmation and receive the advance payment, we will prepare the machines and goods. Usually could ready within 10 working day, when dispatch, will inform client and send the documents for client making import customs clearance.


FAQ 5. What quality will be ensured?

100% new and quality inspection before delivery from factory.

Stable export box for good package.


FAQ 6. Can you guide the working?

The machine will deliver with English display, English manual and video for installation and operation.


FAQ 7. How can your engineer replace parts if they are not beside the machine?

Bonnin’s engineer could provide the solutions by email and video. In warranty period, we can send spare parts for free and life-time technical support for spare supply.


China DSC-600 DSC Differential Scanning Calorimetry TGA DTA DSC Analyzer supplier

DSC-600 DSC Differential Scanning Calorimetry TGA DTA DSC Analyzer

Inquiry Cart 0