50mA 0.5 W Optical Dissolved Oxygen Sensor For Aquaculture


Feature

1.Free from chemical interferences such as sulfides

2.Small annual drift, fast response, and more accurate measurement

3.Free of maintenance, longer application cycle and lower cost of use

4.Fluor cap replacement is simple

5.Support RS-485, MODBUS protocol


Technical Parameters


ItemParameters
ModelDS380
PrincipleFluorescence analysis method
Measuring range0~20mg/L or 0-200% saturation
Response time3 sec
Accuracy1%
Protection levelIP68
InstallationSubmersible
Temperature sensorNTC
Temperature range0~50°C
Temperature accuracy±0.2°C
OutputSupport RS-485, MODBUS protocol
Power supplyDC 6~12V, current <50mA
SizeΦ26*155 mm
Probe cable lengthDefault 5 m, customized 10m, 15 m and 30 m cable
Fluorescent cap life1 year
Maximum working pressure6bar
product materialPOM/SS316/Titanium alloy
Calibration methodOne or Two-point calibration
Power consumption< 0.5 W

ErrorPossible causesSolutions

The operation interface cannot be connected or do not display measurement results


Controller and cable

connection error

Reconnect the

controller and cables

Cable failurePlease contact us

The fluorescent cap is not

tightened or damaged

Reinstall and tighten the fluorescent cap or replace the fluorescent cap

The measured value is too high,

too low or the value is continuously unstable


The outer surface of the fluorescent cap is attached by foreign objectsClean the outer surface of the fluorescent cap and agitate the probe during measurement
Fluorescent cap is damagedReplace the fluorescent cap
The fluorescent cap has exceeded its service life

Temperature measurement exceeds measurable range or garbled reading

Controller and cable connection errorReconnect controller and temperature sensor cable
Temperature sensor is attached to foreign objectsGently brush the attachment with a soft brush