Non Maintained Emergency LED Exit Light Downlight 3W 300Lm

Brand Name:Godson or OEM
Model Number:LED Exit Light GS-068
Minimum Order Quantity:50PCS
Payment Terms:T/T
Place of Origin:Guangdong, China (Mainland)
Price:Negotiable
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Unit 103B (Main Building), Building 4, No. 29 North Pier Road, Huang Pu Village, Haizhu District, Guangzhou, Guangdong, China ,510330
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details


Non Maintained Emergency LED Downlight White 2.5W 130mm EGSMD40/EGSMD50/EGSMD63


Technical Specifications


Mains Supply
AC85-265V-50/60Hz
Power3W
Duration Time3 Hours
Recharge Period16 Hours
Battery Size & Type
lithium battery
/Ni-CD/Ni-MH
LED Power3W
CCT6500k
Luminous Flux300Lm
Size
240*20*190mm
Protection ClassClass
Operating Temperature0-40

Features


- Wall or ceiling mounting
- battery, replaceable
-3 hours emergency duration

Materials
-Base:ABS/PC

What Are Maintained Emergency Lights Types?


Maintained lights are illuminated all the time (24/7) for safety. This means that they switch to a battery-powered emergency output. Even if the power fails, the light will remain on.

This safety light is most commonly an LED, and it should illuminate an exit path and should be easily seen should there be a fire to provide the occupant's safety.

An emergency lighting system in continuous use is called a maintained system. These lighting systems typically remain illuminated 24/7, and each light has dual purposes - one as a regular emergency lamp and another as an emergency light. Maintained lighting systems are often used as escape route lighting and found in buildings such as hospitals or police stations.


What Are Non-Maintained Emergency Lights?


Non-maintained lights usually are not illuminated and will only turn on (illuminate) when the power fails. - The batteries are constantly being charged while ever there is power to the fitting. Power can be cut to a building in the event of a fire. Fire safety security alarm systems can control signs and luminaires. These fire safety systems require appropriate training, building signs and appropriate lighting.


Emergency lighting


While the frequency of testing emergency equipment will be determined by the individual emergency lighting system, as a general guideline, most systems require a monthly inspection followed by a full duration test once a year.


Monthly Testing

This only requires a short test to check that everything is working properly. Use the test key to ensure that all emergency lights are on when the mains power is off and check the enclosures to ensure they are clean and show no signs of damage. Once mains power is restored, check that they are fully charged again.

Also most emergency lights or exit signs have a small "test" button somewhere in the housing. You can press and hold this button for thirty seconds to test the bulb and battery. This method works fine if you have a small number of devices that can be easily accessed. The light should come on and stay at the same brightness level for a full 30 seconds. If the lights dim immediately, or if some bulbs do not work, then you should contact us to replace the bulbs or batteries in the fixture.


Why thirty seconds?

Many defective batteries only hold enough charge to fully light the bulb for a few seconds, but they lose power quickly. If you don't test for 30 seconds, you may find lights that work every month only to find that they go out within seconds of when you really need them. By testing the lights for at least 30 seconds, you can ensure that the batteries have more than just this type of "surface charge".