Add to Cart
Fourth speed variable output Dual Liquids Grout Pump variable pressure
Dual Liquids Grout Pump
Maintenance of Dual Liquids Grout Pump:
Dual liquids grout pump after use and long-stalled or reinstall, before moving to the followingPreparation:
1. Check enough by lubricating oil.
2. Check suction piping water filter, and may not be blocked by dirt, throat hoop clamping hose joint application, guarantee not leak sealing, check the location of the water filter into mud pools, shall generally be in the mud slurry 0.3-0.5 meters below the surface, water filter from pulp bottom position is not less than 0.5 meters holdings.
3. Check all the moving parts and parts for loose or jam phenomenon.
4. Check the clutch and shift gear shifting is accurate, flexible and reliable.
5. Check whether there is any looseness on various fasteners, especially especially M18X1. 5 piston compression nut, connecting the crosshead with the pull rod, etc. Whether to twist.
6. Check grouting machine suction height, at an altitude of 1000 meters, the suction of the pump should be no more than 2.5 meters high, at an altitude of 1000 meters above, should according to the extent of the local atmospheric pressure, reduce the height of the pump.
Parameters of Dual Liquids Grout Pump:
Model | SYB | |
Cylinder diameter | 80mm | |
Motor power | 11kw | |
Grouting capacity | 27-100 L/MIN | |
Outlet pressure | 5-8Mpa | |
Outlet diameter | 19mm | |
Inlet diameter | 25mm | |
Cylinder number | 2 | |
Particle diameter size | ≤5mm | |
Suction Height | 2.5m | |
Weight | 490kg |
Working Performance of Dual Liquids Grout Pump:
This series of hydraulic grouting pumps are professional grouting
equipment, which can realize both single-liquid grouting and
double-liquid grouting. Because of the full hydraulic pressure,
small size and light weight, it can be used in a wide range of
construction. Good adjustability: the pump's pressure displacement
can be arbitrarily adjusted within the design range. When the
pressure exceeds the allowable pressure, the relief valve will
automatically open and the cylinder and working cylinder will stop
working, thus playing a safe role. The motor and air cooler of this
series of grouting pump can be used in flammable and explosive
construction sites such as coal mines after being replaced with
explosion-proof components. A shock-resistant pressure gauge is
installed in the hydraulic system, which can accurately reflect the
working state of the pump. This series of hydraulic grouting pumps
can also be used as water pumps, sewage pumps and mud pumps.
Pictures of Dual Liquids Grout Pump: