diesel driven foundation reinforcement Pneumatic Grout Pump movable
Pneumatic Grout Pump
Transmission of Pneumatic Grout Pump:
There is a refueling hole at the top of the gearbox/transmission,
installed as a vent bolt with a hole, as a vent hole, screw down
the gas bolt can be filled with lubricating oil in the box, the oil
is easy to add to the middle position of the oil window hole, the
rotating parts in the box can splash the lubricating oil into the
oil hole to lubricate the two ends of the support bearings. There
is an oil block at the bottom of the side of the gearbox, which is
easy to replace the lubricating oil in the box. The baffle plate on
both sides can also be removed to observe the gearbox transmission.
Technical parameters of Pneumatic Grout Pump:
Cylinder number | 3 |
Bore diameter | 70mm |
Piston stroke | 70mm |
Diameter of suction pipe | 50mm |
Diameter of outlet pipe | 32mm |
Motor power | 7.5kw |
Main shaft speed | 1450 r/min |
Working pressure | 7 Mpa |
Structure of Pneumatic Grout Pump:
1. Pneumatic Grout Pump is mainly composed of pump body, pump frame, air chamber, shock-resistant pressure gauge, motor, V-belt and pulley cover.
2. The installation foundation of cement grouting pump should be
smooth and not inclined.
3. The pump is fixed on the foundation with the foot screw to
prevent the vibration of the pump during operation.
Preparations before pumping of Pneumatic Grout Pump:
After the pump has been stopped or reinstalled for a long time, the
following preparations must be made before starting.
1. Check whether there is enough lubricating oil in each part.
2. Check whether the suction pipe of the filter is unblocked.
3. Check whether there is obstruction in the movement of each part.
4. Check the accuracy and reliability of the transmission
mechanism.
5. Check the looseness of fasteners, especially the screw
tightening of rubber piston locking nut, cross head and piston rod
connection thread.
6. Check the suction height of the pump. The maximum suction height
of the pump should not exceed 2.5 meters in areas below 1000 meters
above sea level. In areas above 1000 meters above sea level, the
suction height of the pump should be reduced according to the local
atmospheric pressure reduction.
7.Check the position of the filter immersed in the mud tank.
Generally, the mud level should be below 0.3-0.5 meters, and the
filter should be no less than 0.5 meters away from the bottom of
the mud tank.