ROHS 50Hz Constant Temperature Chamber , Multifunctional Humidity Testing Equipment

Brand Name:GSKA
Certification:CE SGS ROHS UL CE
Model Number:Temperature Humidity Chamber
Minimum Order Quantity:Negotiate
Delivery Time:10-60days after confirmed payment or by contract stipulation
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Active Member
Location: Dongguan Guangdong China
Address: Room 401, Building 3, No. 10, Longxi Road, Nancheng Street, Dongguan, Guangdong
Supplier`s last login times: within 30 hours
Product Details Company Profile
Product Details

20%~98% RH 408L Temperature Humidity Chamber -40℃~150℃ Air Cooling

Working principle


Easy To Operating Temperature Humidity Chamber (heating and cooling) and humidification is composed of two parts. Through installation in box within top Department of rotating fan, will air row into box achieved gas cycle, and balance box within of temperature, and humidity, by box built-in of temperature, and humidity sensor collection of data, biography to temperature, and humidity controller (micro information processing device) for edit processing, issued thermostat adjustable wet instruction, through air heating unit, and condensation tube and sink within heating evaporation unit of common completed.


Control


English LCD display LCD touch-panel, the screen on the input data, and programmable temperature and humidity, backlight adjustable 17, curve, curve of setting/display value. Can display a variety of alerts, failure occurs through the screen display, eliminating failures, eliminate misuse. Multi-PID control functions, sophisticated monitoring functions, and the data displayed on the screen.


Features:


1. High-texture appearance, the surface handled through the matte stripes, and use of planar non-reactive handles, easy to operate, safe and reliable.


2. Rectangular complex glass window can be viewed the testing sample, windows with anti-sweat heater device that prevents water vapor condensation, and high-brightness PL light.


3. Double-insulated airtight container, which can effectively isolate the internal temperature of leakage.


4. With an external water supply system can be easy to supply water and automatically reuse.


5. Compressor circulatory system from French "Taikang", more effective removal of oil between the condenser and the capillary and use environmentally refrigerants (R23, R404, R507).


6. Controller imported LCD display screen can be displayed measuring values and setting the value and time.


Military Standards:


MIL-STD-810F-507.4 humidity


MIL-STD-810F-501.4 high temperature


MIL-STD-810F-502.4 low temperature


MIL-STD883C test method 1004.2 temperature and humidity cycling test


MIL-STD810D test method 502.2


MIL-STD810 test method 507.2 procedure 3


Inside size
WxHxD (cm)
40x50x4050x60x5050x75x6060x85x8080x95x80100x100x80100x100x100
Outside size
WxHxD (cm)
90x136x94100x146x104100x161x117110x171x137130x181x137150x186x137150x186x157
Temperature
range
-70℃~+100℃(150℃)
(A:+25℃ B:0℃ C:-20℃ D:-40℃ E:-50℃ F:-60℃ G:-70℃)
Humidity range20%~98%R.H. (10%-98%R.H/5%~98%R.H is the specific codition)
Accuracy/
uniformly
±0.1℃;±0.1%R.H./ ±1.0℃;±3.0%R.H.
Accuracy /
volatility
±1.0℃;±2.0%R.H./ ±0.5℃;±2.0%R.H.
Heating /
cooling time
About 4.0℃/min;about 1.0℃/min(5~10℃/mm is the specific condition)
Inside materialStainless steel SUS 304#
Insulation
material
High-temperature high-density amino acid ethyl ester foam insulation materials
Cooling systemAir-cooled/ single-stage compressor(-20℃) ,wind, water cooled/
two-stage compressor(-40℃~-70℃)
Protectioncompressor overload switch, high and low pressure protection switch,
over-humidity-temperature protection switches, fuses, warning system
Accessoriesrecorder(purchase), view window, 50mm testing hole, PL lamp, clapboard, Dry and wet gauze ball
ControllerTEMI580, 880 digital controller from South Korea
CompressorFrance “Tecumseh”
Power1Φ 220VAC±10% 50/60Hz & 3Φ 380VAC±10% 50/60Hz

Safety protection device

(1) Electricity leak protection.


(2) Lightning strike protection, ZRN lightning arrester inside the controller.


2.1 Sensor dates transferred inside the microcomputer.


2.2 Temp. sensors—open circuit or short circuit ( + - OVER )


2.3 The first level over temp. protection


(3) Error detected units


3.1 The second level over temp. Protection—electronic over temp protection unit (Japan).


3.2 The third level over temp. protection.


3.3 Compressor protection—Refrigerants pressure protection & overload protection.(Denmark)


3.4 Extended protection unit— two suppletive ports.


(4) Error protection— power cut off, error reports shown in LCD panel and audible alarm starts.


(5) Dynamic high and low temperature protection.


(6) Ambient temperature protection — The inner chamber and specimens automatically return back to ambient temperature after the operation stop.



We keep good quality and competitive price to ensure our customers benefit ; We respect every customer as our friend and we sincerely do business and make friends with them,no matter where they come from. Each batch of parts is done quality sampling inspection before into the warehouse, and Each product before delivery is tested by the national authoritative third-party inspection agency

More produced:


Temperature Humidity Test Chamber
Walk-in Aging Chamber
Environmental Test Chambers
Thermal Shock Chamber
Fast Temp. Change Test Chamber
Vibration Shaker
Environmental Vibration Chamber
Mechanical Shock Tester
UV Chamber
Xenon Chamber
highly accelerated stress testing
Salt Spray Test Chamber
Paper Packing Test Equipment

Customers Support Services


1. Installation;


2. Training (Training customer employees);


3. Calibration;


4. Preventative maintenance;


5. Replacement parts;


6. Assistance via phone or internet;


7. On-site diagnosis and repair/online diagnosis and repair;


China ROHS 50Hz Constant Temperature Chamber , Multifunctional Humidity Testing Equipment supplier

ROHS 50Hz Constant Temperature Chamber , Multifunctional Humidity Testing Equipment

Inquiry Cart 0