Specifications
Model | YY-1S(YY-5S) | YY-2M(YY-8S) | YY-2T(YY-1) |
Measurement Range | 1~100,000mPa.s (Cps) | 1~2,000,000mPa.s (Cps) | |
Spindles | No.1, 2, 3, 4 Optional : No.0 (Only No. 0 spindle can test 1-10mpa.s) | ||
Temperature probe | No | No | Yes |
Speed | 6, 12, 30, 60 rpm/min | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm/min | |
Accuracy | ±2% (non-newtonian liquid) | ||
PC Software | No | No | Yes |
RS232 | Yes |
Model | YY-6M (NDJ-9S) | |
Measurement Range | 1~6,000,000mPa.s (Cps) | 10-13,000,000mPa.s (Cps) |
Spindles | No.1, 2, 3, 4 Optional : No.0 (Can test 1-10mpa.s) | No.1, 2, 3, 4, 5, 6, 7 (Cannot use No. 0 Spindles) |
Speed | 0.1, 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm/min | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm/min; 0.5, 1, 2, 2.5, 4, 5, 10, 20, 50, 100 rpm/min; 0.5, 1, 2, 2.5, 4, 5, 10, 20, 50, 100 rpm/min; |
Accuracy | ±2% (non-newtonian liquid) | ±1% (Full measurement range) |
Other accessory | RS232C (Optional: Temperature sensor And PC software) | RS232C; Temperature Sensor; PC Software |
Model | YY-2 | YY-2S |
Measurement Range | 1-2,000,000mPa.s (Cps) | 1-2,000,000mPa.s (Cps) |
Spindles | No. 0, 1, 2, 3,4, | No. 0, 1, 2, 3, 4, 21, 27, 28, 29 |
Speed | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm/min 0.5, 1, 2, 2.5, 4, 5, 10, 20, 50, 100 rpm/min | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm/min 0.5, 1, 2, 2.5, 4, 5, 10, 20, 50, 100 rpm/min 0.5, 1, 2, 5, 10, 20, 50, 100 rpm/min |
Accuracy | ±1% (Full measurement range) | |
Other accessory | RS232 Interface; Temperature Sensor; PC software |
1 | Measurement range | 100 mPa•s~2×105 mPa•s (If you select the No.30 spindle, the measurement range can be extended to 4×105 mPa•s) |
2 | Rotor Specifications | No.21, 27, 28 and 29 total 4 pieces of spindles (the No.30 spindle is optional) |
3 | Rotor speed | (5,10,20,50)r/min |
4 | Measurement error | ±1% (F•S); (If you select the No.30 spindle, it will be ±3% (F•S) |
5 | Temperature control range | 45 ℃~200 ℃ |
6 | Temperature control accuracy | ±0.1 ℃ |
7 | Sample cylinder | 20 ml |
8 | Print output | Needle printer |
9 | Communication with the PC | RS232 interface |
10 | Power supply | AC 220V±10%, 50 Hz |
11 | Ambient temperature | 5 ℃~35 ℃ (when the controlling temperature is close to ambient temperature, please run the air conditioner to let the ambient temperature be 5 ℃ lower than the controlling temperature) |
12 | Relative humidity | ≤80% |
FAQ:
1. who are we?
We are Dongguan Yuyang Instrument Co Limited, based in Guangdong,
China. We have our own manufacture.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
Testing Equipment,Tensile Testing Machine,Environmental Test
Chamber,Fire Testing Equipment,Induction Heating Machine
4. why should you buy from us not from other suppliers?
We are a high-tech enterprise which is specialized in developing
and manufacturing Fire Testing Equipment, Building Material Fire
Tester, Wire and Cable Fire Tester, Environmental Test Chamber,
Textile Testing Equipment, Toys Testing Equipment and etc.