Model | Capacity (kg/hr) | Power(KW) | Weight(kg) | Dimension (cm) |
BH-125 | 80-100 | 3 | 95 | 110*35*700 |
BH-150 | 110-150 | 4 | 98 | 115*35*80 |
BH-210 | 200-300 | 7.5 | 280 | 115*45*95 |
BH-230 | 350-450 | 11 | 300 | 138*46*100 |
BH-260 | 500-600 | 15 | 315 | 130*53*105 |
BH-300 | 700-800 | 22 | 600 | 145*62*120 |
BH-360 | 800-900 | 22 | 795 | 160*67*145 |
BH-400 | 1000-1200 | 30 | 1000 | 160*67*145 |
Matters need attention
1. The new machine for the first time must be run or otherwise
can't be used normally.
2. When the pellet machine is working, don't reach into the input
hopper by hand. If necessary, you can use a stick to help.
3. Before the machine is turned on, you need to add a little
mixture before starting. When the machine is shut down, please
leave a little mixture in the machine to prevent the roller and the
template idling.
4. When the machine is working, and the phenomenon of stuck
happens, should immediately stop and make the roller pressed to the
bolt loose, and then restart the machine.
5. Each time the work is completed, the bolt of adjusting roller
must be released.
6. If the machine is used for a certain period of time or squeeze
out a certain amount of pellets and the pellets are made into
pieces or the pellets are broken, the template should be turned to
the bottom, and 2%-4% water should be added to the mixture.
7. Please often check the belt tightness to prevent the emergence
of low yield, belt slippery and so on.
8. Before starting, firstly add gear oil to the gearbox reaching to
2/3 of the horizontal axis. Pellet machine in the first use should
work in low load for 40 hours or so, and then replace the gearbox
gear oil, 100 hours after the regular replacement. All bearings
should be regularly filled with grease.
9. Particle machine works continuously and then the motor fever
reaches to 70 degrees Celsius, it is a normal phenomenon.