1.0mpa Handle Wafer Valve Simple In Structure

Brand Name:Y
Model Number:D373H-10C
Minimum Order Quantity:1000 pcs
Delivery Time:5-8 work days
Payment Terms:T/T
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Shijiazhuang Hebei China
Address: Jianshe South Street, Yuhua District, Shijiazhuang City, Hebei Province, China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

Carbon Steel 1.0 Mpa Pressure Three Eccentricity Wafer Butterfly Valve


Introduction


The handle butterfly valve is simple in structure, small in size and light in weight, and only consists of a few parts. And only need to rotate 90° can be quickly opened and closed, simple operation, and the valve has good fluid control characteristics. When the butterfly valve is in the fully open position, the thickness of the butterfly plate is the only resistance when the medium flows through the valve body, so the pressure drop generated by the valve is small, so it has better flow control characteristics.


structure


It is composed of valve body, disc, bracket, valve stem, electric device, sealing ring and so on


Connest size

Type

Size

LHH1A1B16KG10KG
D1Z-ΦdD1Z-Φd

D373H

-6C/10C

50431123501802001104-Φ141254-Φ18
65461153701802001304-Φ141458-Φ18
80491203801802001504-Φ181608-Φ18
100561384201802001704-Φ181808-Φ18
125641644601802002008-Φ182108-Φ18
150701755552702802258-Φ182408-Φ22
200892086052702802808-Φ182958-Φ22
25011424368027028033512-Φ1835012-Φ22
30011428380038042039512-Φ2240012-Φ22
35012731083538042044512-Φ2246016-Φ22
40014034091545047049516-Φ2251516-Φ26
45015238096048049055016-Φ2256520-Φ26
500152410102048049060020-Φ2262020-Φ26
600154470122548049070520-Φ2672520-Φ30
700165550135564066081024-Φ2684024-Φ30
800190640147064066092024-Φ3095024-Φ33
9002037101545750860102024-Φ30105028-Φ33
10002167701795850900112028-Φ30116028-Φ36
12002548901965850900134032-Φ33138032-Φ39

Main part name and material


Main partpart material
Body,Disc,YokeWCB
Stem2Cr13
Seal ring430+Graphite asbestos

Precautions for storage, installation and use


1. The valve is kept in a dry warehouse. It is strictly prohibited to store it in the open air.

2. Long-term storage, regular maintenance.

3. The valve is installed on the horizontal or vertical pipe, but it should be opened and closed for easy operation.

4. Pressure test should be carried out before installation, and installation can meet the requirements.

5. Pipe and valve cavity should be cleaned before installation.

6. The valve shall not be subjected to large external forces after installation.

7. The medium flow direction should be consistent with the arrow direction of the valve body when installing.

8. The operating conditions shall meet the technical requirements in the performance specification.


Possible faults and elimination methods


Possible faultsCause of the faultMethod of elimination
Leakage of packing

1. Expiration or aging of stuffing

2. The gland bolt is not tightened

1. Replace the packing

2. Tighten the gland bolts evenly

End cap leakage

1. The bolt is not tightened

2. The O-ring is damaged

1. Tighten the bolts.

2. Replace the O-ring

Sealing surface leakage

1. The valve installation direction is inconsistent with the medium flow direction

2. The shutdown is not in place

3. There is scaling on the sealing surface

4. The sealing surface is damaged

1. Check the installation

2. Readjust the screws on the actuator and close them in place

3. Clean up the buildup

4. Re-grind and repair the sealing surface