380V 22KW 3 Phase Variable Frequency Drive Pump Control VFD 3 Phase Converter

Brand Name:CHIFON
Certification:CE,ISO,SGS,EAC
Model Number:FPR500M-22G-T4
Minimum Order Quantity:1pcs
Delivery Time:sample order 2 working days, bulk order 7-10 working days
Payment Terms:L/C, T/T, Paypal
Contact Now

Add to Cart

Active Member
Location: Hangzhou Zhejiang China
Address: No. 25 Xianxing Rd, Xianlin Industrial Park, Hangzhou, Zhejiang, China
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

Pump Control 380V 22KW Variable Speed Drive 3Phase VFD Inverter Mini Series



Product Specification


Basic FunctionSpecification
Maximum output frequency0~500Hz
Carrier frequency0.5kHz~16.0kHz;According to the load characteristics, carrier
frequency can be adjusted automatically
Input frequencyRange :47~63Hz
Control modeV/F Open/closed loop vector control(SVC/FVC)
Speed range1:50(Vector mode 0 ) 1Hz/150% rated torque
Overload capability

G type:150% rated current for 60s;

180% rated current for 3s
P type:120% rated current for 60s;

150% rated current for 3s

Torque boostAuto Torque boost Manual Torque boost; 0.1%~30.0%.
V/F curve V/FFour modes : Line , Multi-point , Square V/F curve, V/F separation
Jog controlJog frequency range:0.00Hz to F0-10(Max frequency)
Accelerate/Decelerate curveLine or S-curve Acc/Dec mode, four kinds of Acc/Dec time Range
of Acc/Dec Time0.0~65000.00s.
DC brakeDC brake frequency: 0.00Hz to Maximum frequency
brake time: 0.0 to 36.0s
brake current value: 0.0 to 100%
Simple PLC, Multi-speed16-speed operating through built-in PLC or control terminal
Built-in PIDClose loop control system can be formed easily by using PID
Automatic voltage
regulating (AVR)
Output voltage is regulated when voltage of the power network changes
Overvoltage and over current
stall control
During operation automatically limits the inverter output current
and bus voltage, to prevent fan over current and overvoltage trip.
Rapid current limiting
function
Minimizing flow failures, protect the normal operation of the inverter
Instantaneous stop non-stopLoad feedback energy compensation voltage is reduced and continues to maintain a short time when change is momentarily interrupted.
Speed tracking startFor high-speed rotation of the motor speed identification, impact-
free smooth start
Rapid current limitRapid software and hardware limiting technology to avoid
frequent converter over current fault.
Virtual IOFive sets of virtual DO, five sets of virtual DI, enables easy logic control.
Timing ControlTiming control: set the time range 0.0Min~6500.0Hour
Multi-motor
switch
Two independent motor parameters, enabling two motors switching control
Bus SupportTwo independent Modbus communication, CAN-Link
Command sourceGiven the control panel, control terminal, serial communication port given. It
can be switched by a variety of ways.
Torque boostAuto Torque boost Manual Torque boost ; 0.1%~30.0%.
Frequency sourceNine kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways.
Auxiliary
frequency source
Nine kinds of auxiliary frequency source. Flexible implementation of auxiliary
frequency tuning, frequency synthesis.
Input terminalSix digital input terminals, one only supports 50khz high pulse input
Two analog input terminals, one support 0V~10V voltage input
One support 0 ~ 10V voltage input or 0 ~ 20mA current input
Output
terminal
One high-speed pulse output terminal (optional open collector type), support of
square wave 0 ~ 50kHz signal output
One digital output terminal
One relay output terminals
Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V
voltage output
Display and operation
LED displayDisplay parameters and status information

The key lock and function selection


Achieve some or all of the keys locked, scope definition section keys
to prevent misuse.
Protection functionInput/output phase failure protection ,Overcurrent protection ;Over
voltage protection; Undervoltage protection; Overheat protection ;
Overload protection
OptionsBrake assembly, PG card
Environment
Application environmentIn-door, free from direct sunlight, dust , corrosive gas, combustible gas, oil mist , steam , water drop and salt .
AltitudeLower than 1000m
VibrationLess than 5.9m/s(0.6g)


Technical characteristics


Product installation


Please pay attention to the following points when installing the FPR500 series frequency converter:

1)Environment temperature:The ambient temperature has a great influence on the converter life. And operating ambient temperature of the converter is not allowed to exceed the allowable temperature range (-10°C~50°C).

1) The installation space requirements are shown in Figure 3 - 1. It is necessary to ensure that the VFD has enough heat dissipation space.Please consider the heat dissipation of other components in the cabinet when reserving space

2)Frequency converter is mounted on the surface of the flame retardant object, there should be enough space around to dissipate heat.

2) Please install the VFD vertically upward to facilitate heat dissipation upward.If there are multiple VFDs in the cabinet, please install them side by side.Where frequency converters need to be installed up and down, please refer to Figure 3 - 2 to install the heat insulation deflector.

3)Please install in places not prone to vibration, the vibration shall not be greater than 0.6g. Pay special attention to stay away from punch and other equipment.

4)Avoid direct sunlight, humidity, water drop places.
5)Avoid places with corrosive, flammable and explosive gas in the air.

6)Avoid places with oil, dirt and metal dust.

7)FPR500 plastic products are built-in products, it needs to be installed and used in the final system. After installation, only the keyboard panel may be exposed on the final shell for operation.The final system shall provide the relevant fireproof, electrical protective and mechanical protective enclosure, etc., and comply with local laws and regulations and relevant IEC standards.