LEAD GLASS FOR X-RAYS

X-Ray Lead Glass is annealed glass that contains lead oxide and other heavy metals. It offers protection against radiation by absorbing the energy of the radiation. Lead glass is used in many medical environments, from dentist offices to hospitals, laboratories where x-rays and other radiation therapy is tested, and even industrial applications like x-ray imaging of welds on airplanes and pipelines.

Lead glass is primarily used to protect x-ray technicians and other bystanders in a medical office building or hospital and researchers in medical environments where x-ray diagnostic imaging is taking place. This glass is used to protect from gamma and x-ray radiation in CT scanners, PET scanners, general x-ray rooms, panoramic x-rays, and many more.

Due to the magnetic component of MRIs, lead glass cannot be used in these environments


Lead Glass Specification

8mm10mm12mm15mm18mm20mm25mm
( 1.7mmpb)( 2.1mmpb)( 2.6mmpb)( 3.3 mmpb)( 3.96 mmpb)( 4.4 mmpb)( 6.71 mmpb)
200* 300200* 300* 8200* 300* 10200* 300* 12200* 300* 15200* 300* 18200* 300* 20-
300* 400300* 400* 8300* 400* 10300* 400* 12300* 400* 15300* 400* 18300* 400* 20-
400* 600400* 600* 8400* 600* 10400* 600* 12400* 600* 15400* 600* 18400* 600* 20-
600* 800600* 800* 8600* 800* 10600* 800* 12600* 800* 15600* 800* 18600* 800* 20-
600* 900600* 900* 8600* 900* 10600* 900* 12600* 900* 15600* 900* 18600* 900* 20-
1000* 8001000* 800* 81000* 800* 101000* 800* 121000* 800* 151000* 800* 181000* 800* 201000* 800* 25
1200* 8001200* 800* 81200* 800* 101200* 800* 121200* 800* 151200* 800* 181200* 800* 201200* 800* 25
1200* 9001200* 900* 81200* 900* 101200* 900* 121200* 900* 151200* 900* 181200* 900* 201200* 900* 25
1200* 10001200* 1000* 81200* 1000* 101200* 1000* 121200* 1000* 151200* 1000* 181200* 1000* 201200* 1000* 25
1200* 1200-1200* 1200* 101200* 1200* 121200* 1200* 151200* 1200* 181200* 1200* 201200* 1200* 25
1500* 900-1500* 900* 101500* 900* 121500* 900* 151500* 900* 181500* 900* 201500* 900* 25
1500* 1000-1500* 1000* 101500* 1000* 121500* 1000* 151500* 1000* 181500* 1000* 201500* 1000* 25
1500* 1200-1500* 1200* 101500* 1200* 121500* 1200* 151500* 1200* 181500* 1200* 201500* 1200* 25
1600* 1000-1600* 1000* 101600* 1000* 121600* 1000* 151600* 1000* 181600* 1000* 201600* 1000* 25
1600* 1200-1600* 1200* 101600* 1200* 121600* 1200* 151600* 1200* 181600* 1200* 201600* 1200* 25
1800* 1000-1800* 1000* 101800* 1000* 121800* 1000* 151800* 1000* 181800* 1000* 201800* 1000* 25
1800* 1200-1800* 1200* 101800* 1200* 121800* 1200* 151800* 1200* 181800* 1200* 201800* 1200* 25
2000* 1000-2000* 1000* 102000* 1000* 122000* 1000* 152000* 1000* 182000* 1000* 202000* 1000* 25
2000* 1200-2000* 1200* 102000* 1200* 122000* 1200* 152000* 1200* 182000* 1200* 202000* 1200* 25
2400* 1200-2400* 1200* 102400* 1200* 122400* 1200* 152400* 1200* 182400* 1200* 20

2400* 1200* 25


Information about lead shielded


  • Lead Glass offers the highest density x-ray lead glass available for the most efficient medical radiation shielding quality, which also allows approximately 85% spectral light transmission.
  • Lead Glass ensures that its materials are uniformly dense and have a high-quality composition, which provides a dependable shielding value.
  • X-Ray Lead Glass is approved for the medical x-ray, gamma, alpha, and beta photon shielding only.
  • X-Ray Lead glass is NOT for thermal neutron or fast neutron shielding. X-Ray lead glass will NOT shield against Magnetic Resonance Imaging (MRI), electro-magnetism or radio-frequency, ultrasound, laser or any non-ionizing types of radiation.

NOTE:

  • Customer must verify lead equivalency meets the shielding requirements of the room
  • Payment will be required to begin fabrication.
  • Once fabrication begins, no cancellations or changes may take place
  • By placing this order and paying you accept and have verified sizes, quantities, lead equivalency, and accept the terms for shipping / receiving and returns / replacement
  • All products must be inspected upon delivery in the presence of the delivery driver. Once the product is received and the delivery receipt is signed, no claims for damage will be entertained. If there is damage, note it on the delivery receipt and contact us immediately.
  • All radiation shielding calculations must be determined by a radiation physicist.
  • A forklift is required for offloading sizes larger than 24" x 24"
  • Our products can only ship to a commercial address. We cannot ship to residential addresses.