100-240V 50/60Hz Patient Ventilator Machine Verified low noise

Brand Name:R55
Payment Terms:T/T
name:medical portable touchscreen siriusmed ventilator
keyword:siriusmed ventilator
Power Source:Electric
Material:Metal, Plastic
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: Beijing Siriusmed Medical Device Co.,Ltd. A-501, Building 13, No.8 Liangshuihe 2nd Street, YiZhuang Economic-Technical Development Area, Beijing,China. 100176
Supplier`s last login times: within 41 hours
Product Details Company Profile
Product Details

Ventilator R55 -Patient settings automatic stored and can be restored quickly


High Performance Compressor

  • Compact size, portable type for easy installing.
  • User convenient display, enable timely effective operate and maintenance efforts.
  • Available to operate in connection with maximum 2 units of ventilator simultaneously.

Verified low noise suitable for long term working in ICU, oil free, overheat protection and high performance dehydration design makes this compressor can be isolated as gas supply.

  • Safety solution & dust-protection, temperature warning system & Auto/manual shut down.
  • High-end air compressor automatically switches from compressor pump and central gas supply.

System Specifications

Pneumatic VentilatorOperating Conditions
  • 12",TFT display, with touch screen
  • VCV, PCV, SIMV-VC, SIMV-PC, CPAP/PSV,

(Optional PRVC,NIV,VS) :见上描述

,BACKUP

  • P-T, F-T, V-T

CO2-time, pulse rate-time,

loop: P-V, F-V ,P-F

  • NI-MH battery, >90mins
  • RS232, VGA, USB, Remote alarm
  • Gas supply: Air, O2, 280kPa -600kPa (41~87 PSI)
  • Power supply: 100-240V, 50/60Hz
  • Temperature: 10-40℃ (Operation),
  • ℃ (Storage)
  • Relative humidity: 5%-95%,

non-condensing (Operation)

    • Atmospheric pressure

    (Operation & Storage): 500hPa-1060hPa

    • Dimensions (H×W×D):

    Ventilator: 455mm x 400mm x 300mm

    Trolley: 565mm X 535mmX 910mm

    • Weight:

    Ventilator: 12.5 kg

    Trolley: 20 kg

    Standards
    • IEC 60601-1, IEC 60601-1-2, IEC 60601-1-8, ISO 80601-2-12
    AlarmUpper limitLower limit

    Tidal volume

    Minute volume

    Oxygen concentration

    Airway pressure

    Respiratory frequency

    ETCO2

    Pulse rate

    Circuit occlusion

    Apnea alarm

    O2 SUPPLY DOWN alarm

    Mains failure alarm

    Battery power low alarm

    Battery discharged alarm

    Alarm silence

    20~3000 mL

    1~99 L

    22~100%, OFF

    1~99 cmH2O

    1~120 bpm

    0.1~13.3 kPa

    31~250 bpm

    (PEEP+15) cmH2O, 15s

    10~60s

    < 280 kPa

    Automatically switch

    < 10 min

    < 5 min

    ≤120 s

    OFF,20~2999 mL

    0~98 L

    20~100%

    0~98 cmH2O

    OFF,1~99 bpm

    0~13.2 kPa

    30~249 bpm

    (PEEP+15) cmH2O, 15s

    10~60s

    < 280 kPa

    Automatically switch

    < 10 min

    < 5 min

    ≤120 s

    SettingParameterMonitoringParameter

    Tidal volume

    Respiratory frequency

    Inspiratory time

    Breath-hold time

    Pressure triggering

    Flowrate triggering

    PEEP

    Pressure support

    Pressure control

    High pressure level

    Low pressure level

    Oxygen concentration

    100% O2

    T-high

    T-low

    freeze

    Expiratory hold

    Inspiratory hold

    Manual inspiration

    20~2500mL

    1~120 bpm

    0.1~12 s

    0~50%

    -20cmH2O[1] ~PEEP 0

    0.5~20 L/min

    0~50 cmH2O

    0~80 cmH2O

    5~80 cmH2O

    5~80 cmH2O

    0~50 cmH2O

    21~100%

    2mins

    0.1~30s

    0.3~30s

    Yes

    Yes

    Yes

    Yes

    Inspiratory tidal volume

    Expiratory tidal volume

    Minute volume

    Spontaneous minute volume

    Spontaneous respiration frequency

    PEEP

    Airway peak pressure

    Mean airway pressure

    Inspiratory platform pressure

    Minimum airway pressure

    Inhaled oxygen concentration

    Airway resistance


    Compliance

    RSBI

    PEEPi

    EtCO2

    0~4000 mL

    0~4000 mL

    0~99 L

    0~99 L/min

    0~120 bpm

    0~120 bpm

    0~100 cmH2O

    0~100 cmH2O

    0~100 cmH2O

    0~100 cmH2O

    -20~100 cmH2O

    15% ~100 %

    0~600 cmH2O/(L/S)

    0~300 mL/cmH2O

    0 ~ 9999 bpm/L

    0~100cmH2O

    0 ~ 100 mmHg


    0-20cmH2O

    • Pneumatically driven and electronically controlled ICU ventilator
    • Widely usage range: Suitable for infants and adults, newborns
    • Sufficient modes of Ventilation: VCV, PCV, SIMV-VC+PSV, SIMV-PC+PSV, SPONT/CPAP+PSV, BACKUP, Manual (Optional for PRVC,VS,NIV-PC,NIV-CPAP, DuoPhasic+PSV ,APRV+PSV,VS)
    • Knob and Hard key input,Easy and fast choose functions and one step start
    • Easy to position ergonomic trolley with two brakes
    • Quick self-test no need frequent interaction from operator
    • Patient settings automatic stored and can be restored quickly
    • Direct setting of ventilation parameters in the main interface
    • 3 waveforms and loops on one interface, quick changeover
    • System log can record 100 alarms


    China 100-240V 50/60Hz Patient Ventilator Machine Verified low noise supplier

    100-240V 50/60Hz Patient Ventilator Machine Verified low noise

    Inquiry Cart 0