Internal power supply:built-in rechargeable li-ion battery for
8-hour battery life
Carefully inspect every cable, every item, for damage. If the
package is damaged, please keep the package temporarily, check
whether all the contents are in good condition against the packing
list, and then dispose of after checking the mechanical and
electrical functions. If the item is incomplete, damaged, or fails
an electrical inspection, please feel free to contact us and we
will fix it for you as soon as possible.
Functions & features
✔All-digital design, anti-baseline drift, anti-ac, anti-myoelectric
interference;
✔Four operating modes: automatic, manual, rhythm and physical
examination mode. The physical examination mode can record the lead
freely, and the rhythm mode can record the 60-second waveform
automatically.
✔Lead off display;
✔Built-in ECG simulator;
✔Both AC and DC, built-in large capacity rechargeable
maintenance-free battery;
✔High resolution thermal matrix printout;
✔Baseline stability test to ensure a neat and beautiful ECG
waveform every time;
✔Standard RS-232 communication interface, USB interface.
● 12-lead synchronous ECG acquisition;
● Equipped with high speed and high sensitivity hot spot recording
system, with print trace depth adjustment function;
● 7-inch high-definition and wide-angle color LCD screen,
capacitive touch control, 12-lead display;;
● Six ECG record combination modes;
● 3 channels/ (3+R) channels/dual-row 6-channels/single-row
6-channels/single/dual-row 12-channels six ECG display combination
modes;
● Accurate ECG automatic diagnosis function, with heart rate
exceeding alarm function, and freely set whether to print the
measurement and analysis report;
● Full keyboard touch input to enter hospital and patient
information;
● With real-time ECG waveform freezing function, it is easy to
grasp the patient's important ECG waveform;
● Manual, automatic, rhythm, physical examination and other
operating modes;
● With RS232 communication interface, USB interface and LAN network
interface;
● External large capacity USB memory, can achieve the storage,
playback and printing of historical data on the computer
Settings
✔Report style. Options: 3CH, 3CH + R, 3CH + 2, 6CH, 6CH + R, 12CH
physical examination, rhythm.
✔Report waveform gain. Options: AUTO, 5mm / mV, 10mm / mV, 25mm /
mV.
✔Report waveform speed. Options: 12.5mm / s, 25mm / s, 50mm / s.
✔Automatically record time. Options: 4 seconds, 8 seconds, 10
seconds, 12 seconds, 24 seconds, 36 seconds, 60 seconds
✔Average QRS. Options: 2 * 6, 2 * 6 + Mark, 3 * 4, 3 * 4 + Mark, 4
* 3, 4 * 3 + Mark, none.
✔Automatic analysis. Options: all, data, conclusion, none.
✔Lead mode. Options: Standard, Europe.
✔Recording mode. Options: automatic, manual.
✔Report specifications. Options: Standard, A4 paper.
✔Automatically adjust the baseline. Options: on, off.
✔Periodic record. Options: every 1 minute, every 1 minute, every 2
minutes, every 3 minutes, every 4 minutes, every 10 minutes, every
20 minutes, every 30 minutes, every 60 minutes, off.
✔Print depth. Options: Concentration 1, Concentration 2,
Concentration 3, Concentration 4, Concentration 5, Concentration 6,
Concentration 7.
✔Print width. Options: fine, standard, coarse.
✔Medical Examination Lead 1. Options: I, II, III, aVR, aVL, aVF,
V1, V2, V3, V4, V5, V6.
✔Medical Examination Lead 2. Options: I, II, III, aVR, aVL, aVF,
V1, V2, V3, V4, V5, V6.
✔Medical lead 3. Options: I, II, III, aVR, aVL, aVF, V1, V2, V3,
V4, V5, V6.
Technical indicators
✔Common mode rejection ratio ≥100dB
✔The input circuit: Float, defibrillation
✔Input loop current ≤0.1чA
✔Sampling rate:12bit/1000HZ
✔Operating mod:Manual/automatic
✔The filter:Power frequency filter, EMG filter
✔Drift filtering: Anti-drift system
✔The input impedance>50MΩ
✔Patient leakage current<10чA
✔Fuse specification:T1.6A/ 250V Ø5×20
✔Recording paper specification: Scroll/folding thermal recording
paper (110mm)
✔Calibration voltage:1mV±3%
✔Polarization resistance voltage:±500m V
✔Time constant≥3.2s
✔Frequency response: 0.05Hz ~ 165Hz
✔Noise level:≤15чVp-p
✔Minimum detection signal≤20чV
✔The feeding speed:12.5 mm/s,25mm/s, 50mm/s
✔The sensitivity:5,10,20 (mm/mV ±5 %)
✔Record:6 channel high-resolution thermal printing
✔The battery:10.8V/2.6Ah(28.08Wh)
✔Overall dimensions:320mm×230mm×78mm
✔Net weight:1.85KG
✔Size of packing box:390mm×300mm×215mm
✔Gross weight:4.5KG