HbA1c Test Analyzer LD-100 POCT Testing Analyzer Fully Automatic Hematology Detection Analyzer

Intended Use

LD-100 (POCT) One-Step HbA1c Testingf Analyzer is intended for the determination of hemoglobin A1c(HbA1c) content in human whole blood. It is a semi-automatic instrument used to analyze glycated hemoglobin which can be used to detect of HbA1c in medical units at all levels in daliy life. LD-100 analyzer uses the fluorescent immunoturbidimetry, he percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Specifications

ModelLD-100
Device category:Fixed
Power connectionDetachable power supply cord
Measurement TimeLess than 3 minutes
Sample Volume4ul
Sample TypeWhole blood
Data storage7000
Measurement RangeHbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating ConditionTemperature:15~35℃
Humidity:15~80%R.H
Storage ConditionAnalyzer:10-60℃; Test kit: 2~8℃
Voltage12VDC-3.33A
Analytical wave-length510nm and 580nm.
CertificationNGSP, IFCC


PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • One-Step Testing, Automatic Detection
  • Protable and convenient
  • Fast test speed and High Accuracy
  • Battery Integrated
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color touch screen without extra instrument

Reliable

IFCC calibratorNormalAbnormalNormalAbnormal
Mean HbA1c%5.49.65.39.2
CV (%)2.5%1.9%2.4%1.8%

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge


Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English; Abnormal alarm function.