Hospital Medical HbA1c Test Analyzer 4ul Sample Automated Haematology Analyzer

Brand Name:LABNOVATION
Certification:IFCC, NGSP, CE
Model Number:LD-100
Minimum Order Quantity:1
Delivery Time:10 work day
Payment Terms:D/A, D/P, T/T
Contact Now

Add to Cart

Active Member
Location: Shenzhen China
Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Supplier`s last login times: within 29 hours
Product Details Company Profile
Product Details

HbA1c Test Analyzer LD-100 Fully Automatic Testing Hematogy Analyzer Medical Use HbA1c Analyzer


Intended Use

This instrument is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood. Testing processis very simple, touch screen for start testing by click. The LD-100 HbA1c Analyzer is a semi-automatic instrument used to analyze glycated hemoglobin. It just need small sample the can do the HbA1c tetsing, very esay operation and it is suitable for the detection of HbA1c in medical units at all levels.

Specifications

ModelLD-100
Sample TypeWhole blood
Weight800gs
Sample Vloum4ul
MethodFuorescent immunoturbidimetry
Operating TypeFully automatic testing
Measurement Timewithin 3 minutes
Sample TypeWhole blood
Data storage7000
Operating ConditionTemperature:15~35℃
Humidity:15~80%R.H
Dimensions220(w)x150(L)x120(H)mm
Shelf-Life of Test Kit9 months
Power connectionDetachable power supply cord
Storage ConditionAnalyzer:10-60℃; Test kit: 2~8℃
Voltage12VDC-3.33A

PRINCIPLE
HbA1c Analyzer uses the (borate affinity) fluorescent immunoturbidimetry. Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently. The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.


Performance Parameters

  • Accuracy:The relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and the relative deviation of the test results is not more than ±3%.

Feature

  • Boronate Affinity
  • Battery Integrated
  • Portable, Compact
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • External printer (Blue-tooth)
  • USB Port, LIS Support
  • Operating mode: Continuous
  • Easy for use

Reliable

IFCC calibratorNormalAbnormalNormalAbnormal
Mean HbA1c%5.49.65.39.2
CV (%)2.5%1.9%2.4%1.8%

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge


Certificated