Product Details
Hematology Analyzer Reagents Medonic Hematology Reagent For Medonic
3 Part Diff Analyzers
Intended Use
To be used for blood cell counting, sizing, and WBC
differentiation, hemoglobin determination on Medonic 3 part diff
hematology analyzers. This product is for In Vitro Diagnostic Use
only.
APPLICABLE INSTUMENT
For use with Medonic CA620, CA610, CA570, CA530 hematology
analyzers.
Specification
88-10-020 | DILUENT CA | 20L |
88-30-005 | LYSER CA | 5L |
88-40-005 | CLEANER CA | 5L |
KIT COMPOSITION
DILUENT CA | NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0% |
LYSER CA | Quaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5% |
CLEANER CA | Buffer<0.9% , Sufurctant<1.0% |
Procedures
- Remove all the reagent aspiration tubes from the currently used
reagent boxes or bottles.
- Wipe the tube’s surface with a lent free tissue, and then rinse
with distilled water.
- Put the tubes into the LABNOVATION reagent boxes or bottles.
- Run at least 50 backgrounds. Check for the acceptable values. At
first high background counts can be seen, that should lower to
normal after a few runs.
- Run all three levels of a dedicated commercial control. Check for
the acceptable values.
- Recalibrate the unit if necessary.
Advantage
- One source for all brands of analyzer
- Reagents for both 3-parts and 5-parts
- Ready-to-use final products and bulk OEM reagents
- ISQ13485:2003 and ISO9001:2008 certified
- CE marked, FDA cleared
- Well-established brand used by thousands of lab in 95 countries
- High quality, high performance and high fidelity of correlations
with original brand
Storage
- Store the product at 5-35℃ in a dust free place with good
ventilation. Temperature outside the range may damage the product.
- The open vial life of the product is 30 or 60 days (according to
the table above). Unused reagents should be discarded after period
of validity. Do not mix residual with a new carton.
88-10-020 | DILUENT CA | 24 months | 60 days |
88-30-005 | LYSER CA | 24 months | 30 days |
88-40-005 | CLEANER CA | 18 months | 30 days |
PRECAUTIONS
- Re-calibration is recommended when changing the origin of the
reagents.
- It is not recommended using different brands of solutions together
on one unit of analyzer.
- Do not ingest. Avoid contact with skin and eyes.
- Skin contact: Flush with plenty of water.
- Eyes contact: Flush with plenty of water. Obtain immediate medical
attention.
- This kit is for professionals and in vitro diagnostic use only.
FAQ
We have the limit order which is 10000, we would like to cooperate
with you, don't worry about MOQ, just send us of your what items
you want order.
Stock 3-7 days in general. Or please contact us by email for
specific lead time base on your order quantities.
Yes, we accept both OEM and ODM for customers.
- What are your terms of delivery?
We can accept EXW, FOB, CIF, etc. You can choose one which is the
most convenient for you.
- Manufacturer or Trade Company?
We're Manufacturer.
Company Profile
Labnovation Technologies, Inc. is an original manufacturer
established in Shenzhen, China since 2001. We are dedicated in
developing and manufacturing IVD instruments and reagents including
HbA1c analyzer and reagents, rapid test reader & reagents,
hematology reagents, clinical chemistry reagents, electrolyte
reagents, wash solution and urine test reagents.
Labnovation products are developed in house, tested extensively in
clinics and passed strict quality controls. All of our products are
CE marked and approved by SFDA. In the past 15 years, our products
have been exported to 110 different countries and used in 8000
hospitals worldwide. We provide both ready-to-use final products
and bulk OEM reagents, including ready-to-use reagents,
concentrated, and powder.
With an investment of 10% of our annual sales into R&D, we
release new products every years. We win more and more domestic and international cooperation by
company reputation and products quality while we actively take part
in fairs like MEDICA,AACC, ARBA HEALTH and so on through which we
are well-known by the companies in this field.