Product Details
Rapid Test Kit SARS-CoV-2 Neutralizing Antibody Rapid Test Kit High
Accuracy Antibody Rapid Test Kit
Intended Use
The Labnovation's SARS-CoV-2 neutralizing antibody rapid test kit
is intended for the semi-quantitative determination of neutralizing
antibodies to SARS-CoV-2 in human serum, plasma, fingersitick whole
blood or venous whole blood specimens.
Specifications
Test Item | Neutralizing Antibody Test Kit |
Number | LX-401701 |
Sample Volume | Whole blood , Serum, Plasma |
Package | 20 Tests/Kit |
Specificity | 98.00% |
Sensitivity | 97.67% |
Accuracy | >95% |
nspection Method | Immunochromatography |
Shelf Life | 18 Months |
Type | IVD Antibody Rapid Test |
Humidity | 35%-60% |
Main Components
- Test cassettes
- Disposable pipettes
- Sterile Safety Lancets
- Sample Buffer
- Colorimetric chart
- Package Insert
Product Feature
- Privacy
- Accurate
- Sensitivie
- Fast
Advantage
- High Accurate, Sensitivity and Specificity
- Easy to administer and read results: no need for instrument or
other equipment during the test
- Fast detection: the result appears in 15 minutes, can be used for
testing on a massive scale.
- No specific storage requirement: room temperature
Use Step
- Place the lanceton the test site.
- Push down the lancet.
- Collect the bloodby transfer pipette.
- Add one drop of blood into the sample well.
- Add 1-2 drops (30-60µL) of sample buffer into the sample well
innediately.
- Wait 15 minutes then read the result.
Interpretation of results
- POSITIVE: The T line and C line are both displayed within the
reaction window, indicates the neutralizing antibodies to
SARS-COV-2 are detected. The result is positive.
- NEGATIVE:The C line is displayed within the reaction window only,
indicates absence of neutralizing antibody to SARS-COV-2.The result
is negative..
- INVALID:1. If the control (C) line is not displayed in 15 min, regardless
of whether T line is present, the test result is invalid. It is
recommended that the specimen should be re-tested.
The test result is invalid after 20 min.
Storage and Expiry
- The kit should be sealed and stored at 2-30°C, protected from
light, heat, and stored in a dry place. The validity period is
tentatively set at 24 months and cannot be stored in freezing.
- Do not open the inner packaging until ready, it must be used in one
hour if opened (Humidity: 35%-60%, Temp: 20°C-30°C). Please use
immediately when the humidity >60%.
FAQ
We have the MOQ limit,which is 10000 pieces.
After order confirmed,we will arrange your order immediately,and
offer you an
estimated delivery date.
Business to business account.
We choose Air cargo or Ocean cargo.
- Trade Company or Manufacturer:
Manufacturer
Company Profile
Labnovation Technologies, Inc. is an original manufacturer
established in Shenzhen, China since 2001. We are dedicated in
developing and manufacturing IVD instruments and reagents including
HbA1c analyzer and reagents, rapid test reader & reagents,
hematology reagents, clinical chemistry reagents, electrolyte
reagents, wash solution and urine test reagents.
Labnovation products are developed in house, tested extensively in
clinics and passed strict quality controls. All of our products are
CE marked and approved by SFDA. In the past 15 years, our products
have been exported to 110 different countries and used in 8000
hospitals worldwide. We provide both ready-to-use final products
and bulk OEM reagents, including ready-to-use reagents,
concentrated, and powder.
With an investment of 10% of our annual sales into R&D, we
release new products every years. We win more and more domestic and international cooperation by
company reputation and products quality while we actively take part
in fairs like MEDICA,AACC, ARBA HEALTH and so on through which we
are well-known by the companies in this field.