Product Details
Rapid Test Kit SARS-CoV-2 Antigen Rapid Test Self Testing Antigen
Rapid Test Kit
Intend Use
- The rapid test kit is intended for the qualitative detection of
SARS-CoV-2 viral nucleocapsid antigens.
- The antigen test result can be used for early isolation of patients
with suspected infection, but it cannot be used as diagnosis basis
of SARS-CoV-2 infection.
- Further nucleic acid detection should be carried out for suspected
population whose antigen test result is positive or negative.
Product Details
Item | Value |
Model Number | LX-401302 |
Package | 1 Test/Kit |
Specificity | 100.00% |
Sensitivity | 97.45% |
Total Accuracy | 99.17% |
Sample Type | Nasopharyngeal Sample |
Sample volume | 3 Full drops |
Test Time | < 15 minutes |
Warranty | 24 Months |
Quality Certification | CE, MSDS |
Safty Standard | ISO13485, ISO9001 |
Test Principle
- Immunochromatography assay
- Detects SARS-CoV-2 nucleocapsid antigen in the samples with the
help of the double antibody sandwich method.
- This complex “migrates” across the membrane and binds to the
monoclonal antibody at the Test line (T).
- If there is virus antigen presence in the sample, it binds with the
corresponding colloidal gold antibody.
- If the sample does not contain any antigen, then the complex cannot
be formed and thus no reddish line forms in the Test line (T).
Regardless of whether the sample contains antigen or not, a reddish
line forms in the Control line (C).
- In the testing process this will creates a visible red line, you
can accroding the red lin to judge the sample contain antigen or
not.
- It need to be attention that regardless of whether the sample
contains antigen or not, a reddish line forms in the Control line
(C).
Product Feature
- High Accuracy,Specificity and Sensitivity
- Test result within 15 minutes
- 24 Months Shelf Life
- Nasal Swab available
- Easy to operate and requires no additional equipment
- Test at home
Main Components
- 1 Test Cassette
- 1 Sample Tube
- 1 Extraction Buffer
- 1 Swab
- 1 Instruction for use
Use Step
- Open the sealed pouch and remove the test casstette. Lay it face up
on a clean, dry and flat surface.
- Unpack the sample extraction, add all of the sample extraction into
the sample tube and then put the tube into tube stand.
- Gently, insert the entire absorbent tip of the swab (around 1.5 cm)
into your nostril. Rotate walls of your nostril 5 times or more.
Use the same swab to repeat steps in the other nostril.
- Insert the swab into the ssample tube with extraction buffer. Mix
well. Mix well and squeeze the swab 10-15 times by compressing the
walls of the tube against the swab. Roll the swab head against the
inner wall of the tubes as you remove it.
- Close the cape of the sample tube. Add 3 full drops of the mixed
solution vertically into the sample well(S) of the test cassette.
- Read the result 15-20minutes after adding the sample. Result got
after 20 minutes is invalid.
Result Interpretation
POSITIVE: Two colored bands appear on the membrane. One band appears in the
control region (C) and another band appears in the test region (T).
NEGATIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).
INVALID: If there is no Control line (C) or only a Test line (T) in the result window, the test did not run correctly and the
results are not valid.
Virus Sources
Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
B.1.1.33.etc | C.1.1.etc. | |
Certificate
Company Profile
Labnovation Technologies, Inc. is an original manufacturer
established in Shenzhen, China since 2001. We are dedicated in
developing and manufacturing IVD instruments and reagents including
HbA1c analyzer and reagents, rapid test reader & reagents,
hematology reagents, clinical chemistry reagents, electrolyte
reagents, wash solution and urine test reagents.
Labnovation products are developed in house, tested extensively in
clinics and passed strict quality controls. All of our products are
CE marked and approved by SFDA. In the past 15 years, our products
have been exported to 110 different countries and used in 8000
hospitals worldwide. We provide both ready-to-use final products
and bulk OEM reagents, including ready-to-use reagents,
concentrated, and powder.
With an investment of 10% of our annual sales into R&D, we
release new products every years. We win more and more domestic and international cooperation by
company reputation and products quality while we actively take part
in fairs like MEDICA,AACC, ARBA HEALTH and so on through which we
are well-known by the companies in this field.