Product Details
Rapid Antibody Test Kit IgG/IgM Antibody Testing Dengue Antibody
Test 25 Tests Professional Use
Intenden Use
The Dengue IgG/IgM Antibody Test Kit is a rapid chromatographic
immunoassay for the qualitative detection of antibodies (IgG and
IgM) to dengue virus in serum/plasma/whole blood to aid in the
diagnosis of Dengue viral infection.
Specifications
Test Item | Dengue IgM/IgG Antibody Rapid Test Kit |
Sample Type | Serum, Plasma, Whole Blood |
Sample Volume | 1 Full Drop (30 μl) |
Package Size | 25 Tests/Box |
Product Shelf Life | 24 Months |
Test Speed | Within 15 minutes |
Storage Condition | Store 2-30℃ |
Humidity | ≤60% |
Product Features
Accuracy: High Sensitivity, Specificity and Total Accuracy
Flexible: Can use serum, plasma and whole blood
Simple: Sinple operation, one step to use
Fast: Quck recation, read the result within 15 minutes
Advantages
- Simple: simply add specimen and dilution into sample well.
- Rapid: results come out at 10-15 minutes
- Visually interpreted: dont need any equipment
- Stable: Long shelf life
Main Components
- 25 Test Cassettes
- 25 Disposable Pipettes
- 1 Specimen Buffer
- 1 Instruction Manual
Analytical Resualts
Item | IgG | IgM |
Specificity | 98.46% | 98.44% |
Sensitivity | 96.19% | 95.37% |
Accuracy | 97.67% | 97.33% |
Use Step
- Take off the outer packing, put the cassette onto the desk with the
sample window up.
- Drop 1 drop (30μl) of serum/plasma/whole blood vertically into the
sample well of cassette. Add about 2 drops (80-100μl) of specimen
buffer into the sample well of cassette.
- Observe the test results immediately within 15-20 minutes, the
result is invalid after 20 minutes.
Interpreation Of Result
- Two distinct red lines appear. One line should be in the control
region (C) and another line should be in the IgG test region (T1),
indicating the Dengue IgG positive.
- Two distinct red lines appear. One line should be in the control
region (C) and another line should be in the IgM test region (T2),
indicating the Dengue IgM positive.
- Three distinct red lines appear in the control region (C), the IgG
test region (T1) and the IgM test region (T2), indicating the
Dengue IgG and Dengue IgM positive.
- NEGATIVE: One red line appears in the control region(C). No apparent red or
pink line appears in the test region (T1 and T2).
- INVALID: No red bands appear or control line fails to appear, indicating
that the operator error or reagent failure.
Precautions
- For IN VITRO diagnose only.
- Do not use after the expiration date.
- The test result is invalid over 20 minutes.
- The strength of the quality control line does not indicate the
quality problem of the reagent, a test result that is clearly
visible demonstrates the reagent is effective.
- All samples and reagents should be considered potentially hazardous
and handled in the same manner as an infectious agent after use.
- Do not use other kinds of quality control sample to test the
reagent. Components of different batches cannot be exchanged for
use to avoid erroneous results.
Other Informations
- The results of the reagent are only for clinical reference, which
is not the only basis for clinical diagnosis and treatment.
- Negative result may occur when detecting short-term infected
samples or some second time infected samples, indicating that the
specific antibodies of Dengue IgM does not exist or the
concentration is below the detection limit. Some patients may not
produce enough antibodies to be detected in their body within 7 -
10 days, it may show negative results. For some patients, if the
Dengue infection is still suspected, they need to do a new Dengue
rapid test 3-4 days later.
FAQ
MOQ is 10000 pcs
- How can I get a price of needed product?
Please give your exactly specs details to us. We can give you a
sample and price according to your specification
We choose Air cargo or Ocean cargo.
After order confirmed,we will arrange your order immediately,and
offer you an estimated delivery date.
Business to business account.
- Are you a manufacturer or trading company?
We are manufacturer.
Company Profile
Labnovation Technologies, Inc. is an original manufacturer
established in Shenzhen, China since 2001. We are dedicated in
developing and manufacturing IVD instruments and reagents including
HbA1c analyzer and reagents, rapid test reader & reagents,
hematology reagents, clinical chemistry reagents, electrolyte
reagents, wash solution and urine test reagents.
Labnovation products are developed in house, tested extensively in
clinics and passed strict quality controls. All of our products are
CE marked and approved by SFDA. In the past 15 years, our products
have been exported to 110 different countries and used in 8000
hospitals worldwide. We provide both ready-to-use final products
and bulk OEM reagents, including ready-to-use reagents,
concentrated, and powder.
With an investment of 10% of our annual sales into R&D, we
release new products every years. We win more and more domestic and international cooperation by
company reputation and products quality while we actively take part
in fairs like MEDICA,AACC, ARBA HEALTH and so on through which we
are well-known by the companies in this field.