Semi Automated POCT HbA1c Analyzer Whole Blood Sample Individual Test Cartridge

Brand Name:LABNOVATION
Certification:IFCC, NGSP, CE
Model Number:LD-100
Minimum Order Quantity:1
Delivery Time:15-20 working days
Payment Terms:D/A, D/P, T/T
Contact Now

Add to Cart

Active Member
Location: Shenzhen China
Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Supplier`s last login times: within 29 hours
Product Details Company Profile
Product Details

POCT HbA1c Analyzer Semi-Automated Analyzer Individual Test Cartridge​


The POCT HbA1c Analyzer Semi-Automated Analyzer Individual Test Cartridge For Glycosylated Hemoglobin Hba1c Test is a automated desktop point-of-care analyzer for measuring glycated hemoglobin (HbA1c).
The Test Cartridge is individually packaged containing the reagents necessary for the determination of hemoglobin A1c one test.



Principle

The analyzer works based on the principle of boric acid affinity fluorescence quenching. The content of HbA1c is quantitatively detected by detecting the amount of fluorescent substance changing with the binding and quenching of HbA1c and fluorescent



Feature


Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).



Specification


ModelLD-100
MethodBoronate Affinity
Measurement Time≤2 minutes
Sample TypeWhole blood
Measurement Range4.0-15%
Sample Volume4μL
Shelf life of test kit9 months
Weight≤800g
Dimensions192(L)*128(W)*108(H)mm


Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English; Abnormal alarm function.