AC 250V/10A 1 Channel Relay Module Board Shield timer switch relay
module
1.SPECIFICATION
Module Functions:
User can select from below eight functions, by using the key
buttons onboard. User can select and save the set parameters. The
set time is 1 second at minimum, and precision is better than 0.1
second. The eight functions are as follows:
Functions:
1.Timing pick
2.Timing disconnect
3.Timing pull off again
4.Timing disconnect and then pull
5.Infinite loop timing mode1
6.Infinite loop timing mode2
7.Finite loop timing mode1
8,Finite loop timing mode2
9.Latching telay mode
10.Trigger relay mode
11.Pull trigger timing
12.Trigger timing off
13.Pull trigger timing disconnect
14.Discoonect and then pull the trigger timing
15.Infinite loop timing mode 1
16,Infinite loop timing mode 2
17.Finite loop timing mode 1
18.Finite loop timing mode 2.
1)Close upon the set time: after power one, the delay time T1
reaches, and the relay closes. T1 is adjustable between 0 second to
270 hours. When we feed CH1 a high level pulse signal, the cycle
repeats itself (the high level time lasts longer or equal to 20ms.
Same applies to below).
2)Disconnect upon the set time: when the relay closes, the delay
time T1 reaches, and the relay opens. T1 is adjustable between 0
second to 270 hours. When we feed CH1 a high level pulse signal,
the cycle repeats itself.
3)Cycle Mode 1: after power on, the relay does not close at first.
When T1 reaches, the relay closes. When T2 reaches, the relay
opens. And the cycle goes on. T1 and T2 adjustable between 0 second
to 270 hours. When we feed CH1 a high level pulse signal, the cycle
repeats itself.
4)Cycle Mode 2: after power on, the relay immediately closes. When
T1 reaches, relay opens; when T2 reaches, the relay closes again,
and the cycle goes on. When we feed CH1 a high level pulse signal,
the cycle repeats itself.
5)Self-lock relay mode: we feed CH1 a high level pulse signal,
relay closes. When we again feed a high level pulse signal, the
relay opens.
6)Trigger relay mode: we feed CH1 a high level signal, relay
closes. When the high level finishes, the relay opens.
7)Limited cycle mode 1: on basis of function 3, we increase the
cycles. Under this mode, T1 and T2 are adjustable between 0 second
to 9999 second, the cycle is selectable between 1 to 9999 times.
8)Limited cycle mode 2: on basis of function 4, we increase the
cycles. Under this mode, T1 and T2 are adjustable between 0 second
to 9999 second, the cycle is selectable between 1 to 9999 times.
2.PICTURE
Yueqing Kampa Electric Co.,Ltd. is Established in 1990.Has variety of goods ,such
as Relay,Circuit breaker,Switches,Thermocouple,Thermostat,Temperature controller,
Switch power supply,AVS,Heat sink,Heater,Distribution box,Junction
box and so on.
We are manufacturer and have ten years experience in Electrical
industry.
A.Punctual delivery time:
We carry out your order into our well-organized production
schedule, ensure your punctual delivery time.
Production report before your order packed.
Shipping notice and photos sent to you as soon as your order is
shipped.
B.After sales service:
We Pay high Attention To Your Feed back after receive the goods.
We Provide 12 months warranty after goods arrive.
We Promise All Parts Available in lifetime use.
We Positively Revert Your Complain Within 48hours.
C.Professional Sales:
We value every Inquiry Sent To Us, Ensure Quick Competitive Offer.
We Cooperate With Customer To Bid Tenders. Provide all Necessary
Documents.
We Are A Sales Team, With AllTechnical Support From Engineer Team.