QO116C06RCBO10 1P-Ns 10mA 30mA RCBO residual current circuit breaker overload protection

Brand Name:Kampa
Model Number:QO116C06RCBO10
Minimum Order Quantity:1000 Pieces
Place of Origin:Zhejiang, China
Product name:QO116C06RCBO10 1P-Ns 10mA 30mA RCBO
Breaking capacity:10KA
Contact Now

Add to Cart

Active Member
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details
Main
Circuit breaker applicationDistribution
RangeSquare D
Product nameQOvs RCBO
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Poles description1P + Ns
[In] rated current16 A at 40 °C
Earthing systemTN
Curve codeC
Earth-leakage sensitivity10 mA
Breaking capacityIcn : 6000 A - 230/240 V - AC at 50/60 Hz
Complementary
Number of protected poles1
Device location in systemOutgoer
Network typeAC
Network frequency50/60 Hz
[Ue] rated operational voltageUe: 230/240 V - AC at 50/60 Hz
Trip unit technologyThermal-magnetic
Residual current tripping technologyVoltage dependent with functional earth
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
[Icw] rated short-time withstand currentIcw: 250 A during 8/20 µs impulse withstand
[Ics] rated service breaking capacityIcs: 6000 A - 230/240 V - AC at 50/60 Hz
Electrical insulation classClass II
[Ui] rated insulation voltageUi: 400 V - AC at 50/60 Hz
[Uimp] rated impulse withstand voltageUimp: 4 kV
Suitability for isolationYes
Contact position indicatorYes
Control typeToggle
Local signallingON/OFF indication
Mounting modePlug-on
Mounting supportSocket
Comb busbar and distribution block compatibilityNO
Height110 mm
Width19 mm
Depth85 mm
Product weight186 g
ColourBlack
Mechanical durability20000 cycles
Electrical durability5000 cycles
Provision for padlockingNon padlockable
Connections - terminalsPlug-in connector connection on top
Tunnel type terminal connection on bottom - 1...16 mm² - rigid - without cable end
Tunnel type terminal connection on bottom - 1...10 mm² - with cable end
Tunnel type terminal connection on bottom - 1...10 mm² - flexible - without cable end
Wire stripping length15 mm on bottom of power circuit
Tightening torque2 N.m on bottom of power circuit
Earth-leakage protectionIntegrated
Environment
StandardsIEC 61009-1
IEC 61009-2-2
TIS 909-2548
Product certificationsTISI
IP degree of protectionIP20
Tropicalisation2
Relative humidity95 % at 55 °C
Ambient air temperature for operation-15...60 °C
Ambient air temperature for storage-40...85 °C























































China QO116C06RCBO10 1P-Ns 10mA 30mA RCBO residual current circuit breaker overload protection supplier

QO116C06RCBO10 1P-Ns 10mA 30mA RCBO residual current circuit breaker overload protection