Add to Cart
160~250KW 60HZ ROTARY OIL-INJECTED SCREW GA160+~250 ATLAS AIR COMPRESSOR
HIGHEST RELIABILITY, LOWEST OPERATING COSTS
The shortest route to maximize your profitability is to minimize your operational cost. As energy consumption is the major factor (up to 70%) of a compressor’s lifecycle cost, the Atlas GA 160 + -250 compressors are designed to help you achieve significant savings. The compressors provide high-quality compressed air to meet your requirements even in the most demanding applications.
Specifications
TECHNICAL SPECIFICATIONS GA 160 + -250 (60 Hz) | ||||||||||
COMPRESSOR TYPE | Pressure variant(bar) | Max. working pressure WorkPlace | Capacity FAD* | Installed motor power | Noise level** | Weight WorkPlace | Weight WorkPlace Full Feature | |||
bar(e) | psig | l/s | m³/min | cfm | hp | dB(A) | kg | kg | ||
GA 160+ 60Hz | 5.5 | 5.5 | 80 | 635 | 38.1 | 1346 | 215 | 77 | 4793 | 10567 |
7.4 | 7.4 | 107 | 553 | 33.2 | 1171 | 215 | 77 | 4648 | 10247 | |
9.1 | 9.1 | 132 | 474 | 28.4 | 1004 | 215 | 76 | 4648 | 10247 | |
10.9 | 10.9 | 158 | 440 | 26.4 | 932 | 215 | 76 | 4648 | 10247 | |
GA 200+ 60Hz | 5.5 | 5.5 | 80 | 763 | 45.8 | 1617 | 268 | 77 | 4948 | 10908 |
7.4 | 7.4 | 107 | 680 | 40.8 | 1441 | 268 | 77 | 4948 | 10908 | |
9.1 | 9.1 | 132 | 606 | 36.3 | 1283 | 268 | 77 | 4803 | 10589 | |
10.9 | 10.9 | 158 | 547 | 32.8 | 1159 | 268 | 76 | 4803 | 10589 | |
GA 220+ 60Hz | 7.4 | 7.4 | 107 | 759 | 45.6 | 1608 | 295 | 79 | 5168 | 11393 |
9.1 | 9.1 | 132 | 676 | 40.6 | 1433 | 295 | 78 | 5168 | 11393 | |
10.9 | 10.9 | 158 | 626 | 37.6 | 1326 | 295 | 78 | 5023 | 11074 | |
14 | 14 | 203 | 469 | 28.1 | 994 | 295 | 78 | 5023 | 11074 | |
GA 250+ 60Hz | 7.4 | 7.4 | 107 | 831 | 49.9 | 1761 | 335 | 79 | 5168 | 11393 |
9.1 | 9.1 | 132 | 758 | 45.5 | 1605 | 335 | 78 | 5168 | 11393 | |
10.9 | 10.9 | 158 | 690 | 41.4 | 1462 | 335 | 78 | 5023 | 11074 | |
14 | 14 | 203 | 601 | 36.1 | 1273 | 335 | 78 | 5023 | 11074 |
(1) Unit performance measured according to ISO 1217, Annex C and E,
Edition 4 (2009). Reference conditions:
- Absolute inlet pressure 1 bar (14.5 psi).
- Intake air temperature 20°C (68°F).
(2) A-weighted emission sound pressure level at the work station,
Lp WSA (re 20 μPa) dB (with uncertainty 3 dB). Values determined
according to noise level test code
ISO 2151 and noise measurement standard ISO 9614. Pressure dew
point of integrated refrigerant dryer at reference conditions: 2°C
to 3°C (36°F to 37°F).
FAD (1) is measured at the following working pressures:
Standard
5.5 bar version at 5 bar
7.5 bar version at 7 bar
8.5 bar version at 8 bar
10 bar version at 9.5 bar
14 bar version at 13.5 bar
Reducing your operating costs
The GA 160 + -250 provide maximum output at the lowest energy
consumption. They will reduce your energy bill and your CO 2
emissions. The right core technologies with our experience in
design and manufacture combine to produce a solution to match your
needs. Generous cooling capacity, low pressure drop and a highly
efficient drive train ensure optimum operation over a long
lifetime.
Ensuring your peace of mind
The GA 160 + -250 optimize uptime by keeping your production
running, 24/7. The highly advanced controller ensures optimum
operation by controlling all compressor inputs and outputs.
Mining industry
• Years of experience with thousands of compressors running around
the world.
• High product reliability with maximum uptime even in harsh
conditions.
• Strong global support network to provide 24/7 assistance even in
remote locations.
Energy industry
• Protect downstream equipment and increase component lifetime.
• Integrated water separator with electronic drain as standard.
Metal industry
• Easy and quick installation, with flexible ducting possibilities.
• A complete, ready-to-use solution including all components and
options.
• Low service cost thanks to high accessibility of components and
long service intervals.
General industry
• GA compressors are designed for ultimate efficiency in all your
industrial applications.
• Ideal for machinery operation, plant maintenance, cleaning,
pneumatic tools and controls, sand- and shot-blasting.
THE GA 160 + -250 SETS A NEW STANDARD IN THE INDUSTRY
High-efficiency motor
• TEFC IP55 motor (Class F insulation B rise) protects against dust
and chemicals.
• Continuous operation in ambient temperatures up to 46°C/115°F).
State-of-the-art screw element
• Patented asymmetric rotor profile and meticulous selection of
bearings.
• Low wear and tear leads to increased reliability.
• Proven reliability with thousands of installations throughout the
world.
Cooling module
• Separated oil and aftercoolers for highest efficiency.
• Axial cooling fans driven by separate TEFC electric motors (IP55
protection).
• Low noise level.
Gear-driven transmission
• Maintenance-free; totally enclosed and protected against dirt and
dust.
• Optimal working range of the screw element.
• Bowex coupling to absorb the trust load and increase the
reliability.
Superior air intake filter
• Protects the compressor components by removing 99.9% of dirt
particles > 3 μm.
• Reduces the dust load in the fine filter, doubling the filter
element lifetime without reducing filter efficiency.
Elektronikon ® for advanced monitoring
• Integrated smart algorithms reduce system pressure and energy
consumption.
• Monitoring features include warning indications, maintenance
scheduling and online visualization of machine’s condition.
INCREASE YOUR SAVINGS WITH ENERGY RECOVERY
The Kyoto directives and the continuing depletion of traditional
energy sources mean that businesses throughout the world are making
commitments to significantly reduce overall energy consumption.
Through innovative products and solutions, Atlas helps you achieve
your goals in this area. When it comes to compressed air production
– where energy costs can constitute 70% of total lifecycle costs –
saving energy can also lead to substantial cost savings.
Integrated heat exchanger
Air compression creates heat that is normally wasted in the
coolers. Energy recovery systems designed by Atlas enable the
recovery of most of this heat. Recovery of energy from the shaft
input of the compressor can be up to 94% of the compressor shaft
power. The heat is directly usable as a source of energy in the
form of hot water (85-90°C/185- 194°F). The main module of the
recovery system is built into the compressor. The investment needed
to link the hot oil circuit from the compressor to the existing
water circuit is relatively modest and the time needed before
seeing payback from your investment is generally very short.
SMARTLINK * : Data Monitoring Program
• A remote monitoring system that helps you optimize your
compressed air system and save you energy and cost.
• It offers you a complete insight in your compressed air network
and anticipates on potential problems by warning you up-front.
*Please contact your local sales representative for more
information.
Full optimization - ES system controller
Improve product quality every minute that your facility is in
operation. Atlas 's ES system controllers offer a convenient way to
achieve optimized performance from your low pressure equipment
through a single centralized point of monitoring and control. With
the ES system controller watching over your compressors and
compressed air network, you will have a highly dependable and
energy efficient solution working with your facility to manage
operating costs.
Dual pressure set-point and Delayed Second Stop
Most production processes create fluctuating levels of demand
which, in turn, can create energy waste in low use periods. Using
the graphic Elektronikon ® unit controller, you can manually or
automatically create two different system pressure bands to
optimize energy use and reduce costs at low use times. In addition,
the sophisticated Delayed Second Stop (DSS) runs the drive motor
only when needed. As the desired system pressure is maintained
while the drive motor’s run time is minimized, energy consumption
is kept to a minimum.
OPTIMIZE YOUR SYSTEM