150kva Three Phase Pad Mounted Transformer Distribution oil immersed  12470V & 4160V UL Certified

Brand Name:WINLEY
Certification:UL/cUL,CE,ISO
Model Number:S-150/12.47
Minimum Order Quantity:1unit
Delivery Time:30days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Xiamen Fujian China
Address: No.168,Xiabao Road,Siming,Xiamen,Fujian,China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

150kva Three Phase Pad Mounted Transformer Distribution oil immersed 12470V & 4160V UL Certified


Why choose us


1. The product capacity covers 45-5500KVA, the voltage is up to 34.5KV, and it meets or even exceeds: DOE 2016, IEEE/ANSI (C57.12.34), CSA (C227.4 & C227.5), IEC, DOE, NEMA and other standards..
2. The products have obtained UL/cUL certification (Certificate Number: UL-US-2431836-0, UL-CA-2423202-0), and can apply for UL (partner authorization) according to customer requirements..
3. The products are exported to North America, the Philippines and other places in large quantities. We have rich design and production experience and professional and reliable after-sales service, and can deliver quickly within 7-35 days.



Product Structure


  • HV bushings
  • LV bushings
  • Tap Changer: Adjusts output voltage
  • Insulating Oil: ONAN/KNAN.
  • Oil level gauge
  • Liquid temperature gauge
  • Pressure vacuum gauge
  • Lifting Lugs: Used for transportation.
  • Grounding Terminals
  • Nameplate
  • Load break switch
  • Bayonet fuse
  • ELSP fuse
  • Oil drain valve with sampler
  • Drain valve


Advantage


1)The structure is compact and reasonable, and the volume is small, which is only about one-third of the European-style box change of the same capacity;
2)Fully sealed, fully insulated structure, no need to set up safety barriers, and reliable guarantee for personal safety;
3)There are a variety of power supply schemes for users to choose from, which can adopt terminal power supply and realize ring network or dual power supply;
4)S11 oil-immersed power transformer is adopted, which has low loss, low temperature rise and strong overload capacity;
5)Double fuses (backup protection fuse + plug-in fuse) are used for protection, and the plug-in fuse fuse has the current and temperature dual sensitivity characteristics to ensure the safe and reliable operation of the product;


Main data


Transformer ConfigurationLiquid Filled Pad Mounted
Transformer Feed TypeRadial Feed
PhaseThree Phase
Capacity150 KVA
Vector GroupDyn1
Primary Voltage12470V & 4160V
Primary Voltage SwitchDual Voltage Selector Switch
Primary BIL95 KV
Secondary Voltage208Y/120
Frequency60 Hz
Temperature Rise65°C
Insulation RatingClass E Insulation - 120°C, 248°F
Cooling ClassKNAN; Self-Cooled
Efficiency Standard(s)Meets DOE 2016 Standards, Meets CSA Standards Meets ANSI/IEEE Standards
K-Factor Rating (Harmonic Mitigation)K-4
Winding MaterialCopper
Ambient Temperature Rating40°C
Ambient Operating Temperature Range-40°C to +40°C (-50°F to +104°F)
Sound Level55 dBA
Elevation (Altitude)3300ft (1000 meters) Above Sea Level
Core MaterialGrain Oriented Steel
Efficiency %99.00%

Technical drawings



Application


1)The structure is compact and reasonable, and the volume is small, which is only about one-third of the European-style box change of the same capacity;
2)Fully sealed, fully insulated structure, no need to set up safety barriers, and reliable guarantee for personal safety;
3)There are a variety of power supply schemes for users to choose from, which can adopt terminal power supply and realize ring network or dual power supply;
4)S11 oil-immersed power transformer is adopted, which has low loss, low temperature rise and strong overload capacity;
5)Double fuses (backup protection fuse + plug-in fuse) are used for protection, and the plug-in fuse fuse has the current and temperature dual sensitivity characteristics to ensure the safe and reliable operation of the product;
6)The 200A cable connector can be plugged and unplugged under load, and can be operated as a load switch in an emergency. It also has the characteristics of an isolating switch.
7)The winding adopts Dyn11 connection and the iron core adopts a three-phase four-column structure, so that the product can run under any asymmetric load, and the neutral point does not drift, the voltage is stable, the power supply quality is high, the cabinet heats up, the noise is low, and the lightning protection performance is good ;
8)The cabinet adopts anti-corrosion design and special spray paint treatment, beautiful and novel, suitable for various environments, and achieve the effect of beautifying the city.


Specification


Rated Power
(KVA)
High Voltage
(KV)
Low Voltage
(V)
No-load Loss
(W)
On-load Loss
(W)
Height
(mm)
Depth
(mm)
Width
(mm)
Weight
(kg)
Weight
(Lbs)
75KVA34.5KV
4.160KV
12.47KV
13.2KV
13.8KV
24940GrdY/14400
1247Grdy/7200
4160GrdY/2400
or others
277V
347V
480V
600V
120/240V
208GrdY/120
415GrdY/240
480GrdY/277
600Y/347
1801250143091019306451422
150KVA2802200153098015109892180
300KVA480365016801080166014153119
500KVA680510017901160181019054200
750KVA980750020301300203027556074
1000KVA11501030018541549165132357132
1500KVA164014500215015702210583512864
2000KVA216020645222016002380643014175
2500KVA268023786233016503070886519544
3000KVA3300303002460185032601130024912
3735KVA4125378752680206040801440031746

Production process



FAQ


1. Q: Can I have a sample order?

A: Yes, we welcome sample order to test and check quality.

2. Q: What is the lead time?

A: Mass production time 15-25 days.

3. Q: How long is the warranty?

A: 24 monthes from B/L. If there are any accessory problems,just provide the photos of damaged accessory,then we will provide free service. According to the number of products,we will provide easily damaged accessories for free. we also can provide technical support if you need.

4. Q: Is OEM/ODM available?

A: Yes,it is! We are manufacturer with our own R&D team, we can customize products according to customer's drawing or requirements.

Customized services:

a. Customized color and special function.

b. Customized box.

c. Print customer's logo.

d. Your other ideas about product, we can help you design and put them into production. The above customized services must be confirmed before production.

5. Q: How to control the products quality?

A: Our company owns the core technology ,all kinds of products hold CE certificate. We have professional engineers. Workers are strictly required to make products according to the drawings. Each process has technical instructors.The QC supervisors will regularly inspect the production. We will do products performance tests during production, and comprehensive quality tests when the products is completed.

China 150kva Three Phase Pad Mounted Transformer Distribution oil immersed  12470V & 4160V UL Certified supplier

150kva Three Phase Pad Mounted Transformer Distribution oil immersed  12470V & 4160V UL Certified

Inquiry Cart 0