100kva Single Phase Pole Mounted Electrical Distribution Transformer 34.5KV to 120V


WINLEY supplies pole-mounted transformers that meet your high expectations, including both single-phase and three-phase. Single-phase transformers range from 15 kVA to 333 kVA, three-phase range from 15 kVA to 500 kVA. These transformers comply with ANSI, IEEE, CSA, IEC60076, and other international standards. Through optimized electrical design and the use of high-quality materials and components, our pole-mounted transformers are safe, stable, and efficient, helping you reduce operating costs.


Main data


Transformer TypeOverhead Distribution Transformer, Conventional Type
PhaseSingle Phase
Capacity100 KVA
Primary Voltage34500GrdY/19920
Secondary Voltage120/240V (L-N-L)
Frequency60 Hz
Temperature Rise65°C
Insulation RatingClass E Insulation - 120°C, 248°F
Cooling ClassONAN; Self-Cooled
Efficiency Standard(s)Meets DOE 2016 Standards, Meets ANSI/IEEE Standards
K-Factor Rating (Harmonic Mitigation)K-1 (Standard)
Winding MaterialCopper
Ambient Temperature Rating40°C
Dimensions*30.2''-W x 30.5''-D x 46.1''-H
Total Weight (Liquid Filled)*1608 lbs
Efficiency99.00%
No Load Loss (in watts)+/- 267W
Full Load Loss (in watts)+/- 1,085W

Product Structure


  • Quality System ISO 9001 certified
  • Meet DOE Energy Efficiency Standard or exceeds ANSI/IEEE and CSA standards
  • Lifting lugs
  • Arrester mounting pads
  • Cover-mounted high votage porcelain
  • Bushing(s) with eyebolt terminal
  • Low voltage bushings wtih eyebolt terminals
  • Low voltage enutral grounding strap(not shown)(10-50kVA class B-2 and B-3 only)
  • ANSI support lugs(hanger brackets) with laser inscribed nameplate on lower bracket
  • Polyester insulated cover
  • Self-venting and resealing cover assembly
  • Centerline core/coil assembly support brackets
  • Low voltage leads
  • Oil fill plug with cover ground strap
  • Tank ground pad
  • The fllowing additional features are all standard on self protected type CSP units only
  • Primary protective link (mounted in high voltage bushing)
  • Surge arrester
  • Secondary circuit breaker
  • Secondary breaker operating handle with emergency overload reset and overload signal light

Drawing



Specifications


10kva-500kva Single-phase oil immersed transformer
Rated Cap acity(kVA)HighLow Voltage(v)Connection SymbolStandardShort-circuit impedance(%)Efficiency
Voltage(v)(%)
104160
7200
12000
12470
13200
13800
19920
24940
34500
110
220
230
400
480
II0,II6IEEE/ANSI/ DOE1.8-4%98.7
1598.82
2598.95
37.599.05
5099.11
7599.19
10099.25
16799.33
25099.39
33399.43
50099.49

Pole Mounted Transformer Key Craft


1. Magnetic circuit design
The iron core's shape, size, hysteresis, and eddy current loss are important factors to consider. Properly designing the magnetic circuit can lead to efficient energy transmission and reduced loss.

2. Winding design
Factors such as the number of turns, wire material, interlayer insulation, and wiring method should be taken into consideration during the design process. By implementing a well-planned winding design, the transformer can achieve greater load capacity and reliability.

3. Insulation material selection
Choosing the right insulation materials is paramount to ensure safety and longevity. It's essential to opt for insulating materials that offer excellent insulation performance, high-temperature resistance, arc breakdown resistance, and moisture resistance.

4. Vacuum oil filling
Single-phase pole-mounted transformers typically utilize a vacuum oil filling method. This involves treating the transformer chips with a vacuum, injecting insulating oil, eliminating air bubbles, and sealing the transformers. The vacuum oiling process is beneficial as it enhances the insulation performance and thermal stability of the transformer, leading to prolonged service life.

5. Heat treatment
Transformers' mechanical properties and strength can be enhanced through heat treatment. This process alters the material's organizational structure, boosting its hardness and wear resistance while reducing stress and deformation.


Production process



FAQ


1. Q: Can I have a sample order?

A: Yes, we welcome sample order to test and check quality.

2. Q: What is the lead time?

A: Mass production time 15-25 days.

3. Q: How long is the warranty?

A: 24 monthes from B/L. If there are any accessory problems,just provide the photos of damaged accessory,then we will provide free service. According to the number of products,we will provide easily damaged accessories for free. we also can provide technical support if you need.

4. Q: Is OEM/ODM available?

A: Yes,it is! We are manufacturer with our own R&D team, we can customize products according to customer's drawing or requirements.

Customized services:

a. Customized color and special function.

b. Customized box.

c. Print customer's logo.

d. Your other ideas about product, we can help you design and put them into production. The above customized services must be confirmed before production.

5. Q: How to control the products quality?

A: Our company owns the core technology ,all kinds of products hold CE certificate. We have professional engineers. Workers are strictly required to make products according to the drawings. Each process has technical instructors.The QC supervisors will regularly inspect the production. We will do products performance tests during production, and comprehensive quality tests when the products is completed.

China 100kva Single Phase Pole Mounted Electrical Distribution Transformer 34.5KV To 120V supplier

100kva Single Phase Pole Mounted Electrical Distribution Transformer 34.5KV To 120V

Inquiry Cart 0