China Categories
English
1 - 20 Results for 66kv current transformer from 7421 Products

... Indoor Ring Type Below 0. 1. Introduction LMZ(J)1-0.66 is used indoor with rated voltage below 0.,i...

Time : Dec,09,2024
Contact Now

Add to Cart

Low Voltage RCT 0.66kv and Below Zero Phase CT Wth PCB Mount Used For kWh Meter Description : The RCT current transformers are used in 0.66kv and belo...

Time : Dec,09,2024
Contact Now

Add to Cart

0.66KV SMALL MINI SPLIT CORE CURRENT TRANSFORMER WITH mA or mV output FOR METER Features Most cost-effective Faster installation Safe and easy install...

Time : Dec,09,2024
Contact Now

Add to Cart

...: 720V AC ● Test voltage: 3kV AC(1min) ● Rated frequency: 50/60Hz ● Rated short-time thermal : Ith=40~60In ● Rated dynamic : Idyn=2.5...

Time : Dec,09,2024
Contact Now

Add to Cart

Window DC Contactor Low Voltage Protection Devices 0. / 3KV LMZJ1-0.66 Technical parameter Model Rated c...

Time : Dec,27,2024
Contact Now

Add to Cart

0.66kv current sensor high voltage measurement and protection sensor used in high-voltage ring main units below 10kV SCDFC230-10 current sensor is a n...

Time : Dec,31,2024
Contact Now

Add to Cart

... and also used to voltage or in the circuit. However, voltage and by power aims at...

Time : Dec,09,2024
Contact Now

Add to Cart

.... The split core design permits non-contact measurements through magnetic field induction without disconnecting cables circuits for CT inst...

Time : Dec,09,2024
Contact Now

Add to Cart

...6kA Mainly using for: Clamp-on Clip on clamp Technial index notes T...

Time : Dec,09,2024
Contact Now

Add to Cart

... Lamination 1.Product Description The EI19 Low Frequency is a compact and efficient ...

Time : Apr,17,2025
Contact Now

Add to Cart

... 2, Mainly using for: 1). Clamp-on , 2). Clip on , 3). clamp, 4). 3, ...

Time : Dec,09,2024
Contact Now

Add to Cart

...-CT03 Series The miniature has no resistance at one time, and the ordinary micro is a tr...

Time : Dec,09,2024
Contact Now

Add to Cart

... KH80 Technical Parameters Load capacity <=4ohm (mA output); <=1VA (1A output); <=5VA (5A output, 600-1000A); <=2.5VA (5A output, <=500A) Diameter 80mm Dimension 193*138*28mm Weatherproof Outdoor Split-core IP68 0.5 or 0.2 Class Power Distribution line monitoring outdoor split-core ......

Time : Apr,16,2025
Contact Now

Add to Cart

... connected with the Panel Meter or Relay and they can help to measure the or protect the equipments. Low voltage transformers are m...

Time : Dec,09,2024
Contact Now

Add to Cart

... / MFO : 1.Model:MSQ-30,MSQ-30B,MSQ-30T,MSQ-40,MSQ-60,MSQ-85,MSQ-100,MSQ-125 2.Standard:IEC60044-1 3.Certific...

Time : Dec,09,2024
Contact Now

Add to Cart

... wide range 200A ratio 1:1 KE6323-200 Isolation transformer KE6323-200 Isolation transformer (ICT) is us...

Time : Dec,09,2024
Contact Now

Add to Cart

...transfer, so that the implementation of the action, through the switch device to disconnect the power supply. Similar structure and of ...

Time : Dec,09,2024
Contact Now

Add to Cart

...​ widely applied in electronic energy meter, power transducer, RTU, etc For our , which are produced by usin...

Time : Dec,09,2024
Contact Now

Add to Cart

... of low voltage 1000 to 3000A output 1a or 5a for electric motors Features:Safe, easy to install, portable.W...

Time : Dec,09,2024
Contact Now

Add to Cart

Inquiry Cart 0